FP0807R1-R07-R Datasheet, PDF (1/4 Pages) Cooper Bussmann, Inc. – High Current, High Frequency, Power Inductors | |||
|
High Current, High Frequency, Power Inductors
FLAT-PAC⢠FP0807 Series
SMD Device
Description:
⢠Halogen free
⢠125°C maximum total temperature operation
⢠7.4 x 7.6 x 7.0mm surface mount package
⢠Ferrite core material
⢠High current carrying capacity, Low core losses
⢠Controlled DCR tolerance for sensing circuits
⢠Inductance range from 70nH to 220nH
⢠Current range from 35 to 108 amps
⢠Frequency range up to 2MHz
⢠RoHS compliant
Applications:
⢠Multi-phase regulators
⢠Voltage Regulator Module (VRM)
⢠Desktop and server VRMs and EVRDs
⢠Notebook regulators
⢠Data networking and storage systems
⢠Graphics cards and battery power systems
⢠Point-of-load modules
⢠DCR sensing
Environmental Data:
⢠Storage temperature range: -40°C to +125°C
⢠Operating temperature range: -40°C to +125°C
(Range is application specific)
⢠Solder reflow temperature: J-STD-020D compliant
Packaging:
⢠Supplied in tape and reel packaging, 600 parts per reel,
13â diameter reel
Part Number7
FP0807R1-R07-R
FP0807R1-R10-R
FP0807R1-R12-R
FP0807R1-R16-R
FP0807R1-R18-R
FP0807R1-R20-R
FP0807R1-R22-R
OCL1 ± 10% (nH) FLL2 Min. (nH)
70
50
100
72
120
86
160
115
180
129
200
144
220
158
Product Specifications
Irms3 (Amps) Isat14 @ 25°C (Amps) Isat25 @ 125°C (Amps) DCR (mΩ) @ 20°C
108
79
77
55
66
48
49
48
36
0.50 ± 6%
42
32
38
28
35
25
K-factor6
520
520
520
520
520
520
520
1 Open Circuit Inductance (OCL) Test Parameters: 100kHz, 0.10Vrms, 0.0Adc
2 Full Load Inductance (FLL) Test Parameters: 100kHz, 0.1Vrms, Isat1
3 Irms: DC current for an approximate temperature rise of 40°C without core loss. Derating is
necessary for AC currents. PCB pad layout, trace thickness and width, air-flow and proximity of
other heat generating components will affect the temperature rise. It is recommended the part
temperature not exceed 125°C under worst case operating conditions verified in the end
application.
4 Isat1: Peak current for approximately 20% rolloff at +25°C.
5 Isat2: Peak current for approximately 20% rolloff at +125°C.
6 K-factor: Used to determine Bp-p for core loss (see graph). Bp-p = K * L * ÎI * 10-3, Bp-p : (Gauss),
K: (K-factor from table), L: (inductance in nH), ÎI (peak-to-peak ripple current in amps).
7 Part Number Definition: FP0807Rx-Rxx-R
⢠FP0807 = Product code and size
⢠Rx is the DCR indicator
⢠Rxx= Inductance value in μH, R = decimal point ⢠â-Râ suffix = RoHS compliant
0908 BU-SB08620
Page 1 of 4
Data Sheet: 4343
|
▷ |