English
Language : 

FP0805R1-R03-R Datasheet, PDF (1/4 Pages) Cooper Bussmann, Inc. – High Current, High Frequency, Low-Profile Power Inductors
High Current, High Frequency, Low-Profile Power Inductors
FLAT-PAC™ FP0805 Series
SMD Device
Description
• Halogen free
• 125°C maximum total temperature operation
• 7.5 x 7.6 x 5mm surface mount package
• Ferrite core material
• High current carrying capacity, Low core losses
• Controlled DCR tolerance for sensing circuits
• Inductance range from 32nH to 200nH
• Current range from 20 to 110 Amps
• Frequency range up to 2MHz
• RoHS compliant
Applications
• Multi-phase regulators
• Voltage Regulator Module (VRM)
• Point-of-load modules
• Desktop and server VRM’s and EVRD’s
• Data networking and storage systems
• Notebook regulators
• Graphics cards and battery power systems
• DCR sensing
Environmental Data
• Storage temperature range: -40°C to +125°C
• Operating temperature range: -40°C to +125°C (Range is application
specific)
• Solder reflow temperature: J-STD-020D compliant
Packaging
• Supplied in tape and reel packaging, 950 parts per reel,
13 inch diameter reel.
Part Number7
FP0805R1-R03-R
FP0805R1-R06-R
FP0805R1-R07-R
FP0805R1-R10-R
FP0805R1-R20-R
OCL1 ± 10% (nH) FLL2 Min. (nH)
32
23
58
42
72
52
100
72
200
144
Product Specifications
Irms3 (Amps) Isat14 @ 25°C (Amps) Isat25 @ 125°C (Amps) DCR (mΩ) @ 20°C
110
95
83
61
65
67
49
0.17 ± 17%
50
35
20
16
K-factor6
823.6
823.6
823.6
823.6
823.6
1 Open Circuit Inductance (OCL) Test Parameters: 100kHz, 0.10Vrms, 0.0Adc
2 Full Load Inductance (FLL) Test Parameters: 100kHz, 0.1Vrms, Isat1
3 Irms: DC current for an approximate temperature rise of 40°C without core loss. Derating is
necessary for AC currents. PCB pad layout, trace thickness and width, air-flow and proximity of
other heat generating components will affect the temperature rise. It is recommended the part
temperature not exceed 125°C under worst case operating conditions verified in the end
application.
4 Isat1: Peak current for approximately 20% rolloff at +25°C.
5 Isat2: Peak current for approximately 20% rolloff at +125°C.
6 K-factor: Used to determine Bp-p for core loss (see graph). Bp-p = K * L * ΔI * 10-3, Bp-p : (Gauss),
K: (K-factor from table), L: (inductance in nH), ΔI (peak-to-peak ripple current in amps).
7 Part Number Definition: FP0805Rx-Rxx-R
• FP0805 = Product code and size
• Rx is the DCR indicator
• Rxx= Inductance value in μH, R = decimal point • “-R” suffix = RoHS compliant
1208 BU-SB08859
Page 1 of 4
Data Sheet: 4340