FNA-3 Datasheet, PDF (1/4 Pages) Cooper Bussmann, Inc. – FNQ-R — 600Vac, 1⁄4-30A, Time-Delay Fuses | |||
|
LIMITRON⢠Class CC
FNQ-R â 600Vac, 1â4-30A, Time-Delay Fuses
Dimensions - in
1.5" (± 0.031)
(38.1mm)
0.41" (± 0.005)
(10.3mm)
Description: Advanced protection Class CC current-limiting,
time-delay fuses.
Catalog Symbol: FNQ-R-(amp)
Ratings:
Volts â 600Vac
â 300Vdc (15 & 20A)
Amps â 1â4-30A
IR â 200kA Vac RMS Sym.
â 20kA Vdc (15 & 20A)
Agency Information:
CE, UL Listed, Std. 248-4, Class CC, Guide JDDZ, File E4273
CSA Certified, Class CC CSA, Class 1422-01,
File 53787âHRC-MISC
RoHS Compliant*
* FNQ-R-1â4 not RoHS complaint.
Catalog Numbers (amps)
FNQ-R-1â4
FNQ-R-3â10
FNQ-R-4â10
FNQ-R-1â2
FNQ-R-6â10
FNQ-R-3â4
FNQ-R-8â10
FNQ-R-1
FNQ-R-11â8
FNQ-R-11â4
FNQ-R-13â10
FNQ-R-14â10
FNQ-R-11â2
FNQ-R-16â10
FNQ-R-18â10
FNQ-R-2
FNQ-R-21â4
FNQ-R-21â2
FNQ-R-28â10
FNQ-R-3
FNQ-R-32â10
FNQ-R-31â2
FNQ-R-4
FNQ-R-41â2
FNQ-R-5
FNQ-R-56â10
FNQ-R-6
FNQ-R-61â4
FNQ-R-7
FNQ-R-71â2
FNQ-R-8
FNQ-R-9
FNQ-R-10
FNQ-R-12
FNQ-R-15
FNQ-R-171â2
FNQ-R-20
FNQ-R-25
FNQ-R-30
Carton Quantity:
Amp Rating
1â4-30
Carton Qty.
10
Maximum Acceptable Rating of Overcurrent Deviceâ
Rated Primary
Current (Amps)
< 2A
2A to 9A
> 9A
Maximum Rating of Overcurrent
Protective Device Expressed As a Percent
of Transformer Primary Current Rating
500â â
167
125
â UL 508A Table 42.1.
â â 300% for other than motor control applications.
Features:
⢠Provides 10X better current limitation to help prevent
equipment damage caused by short-circuit events.
⢠200kA interrupting rating complies with NEC® Section 110.9
for today's large capacity systems.
⢠Fast-acting fuse helps prevent equipment damage caused
by short-circuit events.
⢠Rejection type fuse fits both standard and rejection-style
holders.
⢠The Class CC FNQ-R Limitron fuse meets the needs of
control circuit transformer protection.
⢠FNQ-R fuses can be sized according to NEC® and UL
requirements and still allow the high inrush currents, with
significantly more time-delay than the UL minimum value of
12 seconds at 200% for Class CC fuses.
⢠Ideal for critical industrial or commercial applications that
have specific current limitation requirements.
Applications:
⢠Branch Circuits
⢠Small Control Transformers
⢠Line Protection
⢠Industrial Control
Recommended Fuse Blocks and Holders
Fuse Amps
1-Pole
2-Pole
Open Blocks
0-30
BC6031_
BC6032_
DIN-Rail Holders
CHCC1D_
CHCC2D_
0-30
â
â
â
â
â
â
Panel Mount Holders
0-30
HPS
â
HPF
â
In-Line Holders
0-30
â
HEY
HEZ
â
3-Pole
BC6033_
CHCC3D_
OPM-NG-_
OPM-1038_
OPM-1038_SW
â
â
â
â
For additional information on Class CC fuse blocks and
holders, see Data Sheets:
⢠Open Blocks # 1105 (BC Series)
⢠DIN-Rail Holders # 3185 (CHCC), # 1109 (OPM),
# 1102 (OPM-1038), 1103 (OPM-1038_SW),
⢠Panel Mount Holders # 2113 (HPS), # 2114 (HPF)
⢠In-Line Holders # 2126 (HEY), # 2130 (HEZ)
0114
BU-SB14042
Page 1 of 4
Data Sheet # 1014
|
▷ |