1025FA250-R Datasheet, PDF (1/2 Pages) Cooper Bussmann, Inc. – Brick™ Fuses 1025FA Series, Fast-Acting
Brick™ Fuses
1025FA Series, Fast-Acting
Description
• Fast-acting surface-mount fuse
• Satisfies the EIA/IS-722 Standard
• Solder immersion compatible
Electrical Characteristics
% of Amp Rating
Opening Time
100%
4 Hours Minimum
200% (250mA-5A)
5 Seconds Maximum
250% (250mA-5A fuse)
1 Second Maximum
200% (7-15A fuse)
20 Seconds Maximum
250% (7-15A fuse)
4 Seconds Maximum
Note: 30vde constant current source required for 200%
overload tests on 250mA-1A.
Agency Information
• UL Recognition Guide & File numbers:
JDYX2 & E19180 (250mA - 15A)
• CSA Component Acceptance:
File # 053787 C000, Class # 1422 30
Environmental Data
• Life test: MIL-STD-202, Method 108A, Test Condition D
• Load humidity: MIL-STD-202, Method 103B
• Moisture resistance: MIL-STD-202, Method 106E
• Terminal strength: MIL-STD-202, Method 211A
• Thermal shock: MIL-STD-202, Method 107D, air-to-air
• Case resistance: EIA/IS-722
• Resistance to dissolution of metallization:
ANSI J-STD-002, Test D
• Mechanical shock: MIL-STD-202, Method 213B with
exceptions per EIA/IS-722 Standard
• High frequency vibration: MIL-STD-202, Method 204D,
Test Condition D
• Resistance to solvents: MIL-STD-202, Method 215A
Dimensions – mm/in
Drawing Not to Scale
Recomended Pad Layout – mm (in)
3.30
(0.130)
4.38
(0.172)
Ordering
6.79
(0.267)
• Specify packaging and product code
(i.e., TR2/1025FA250-R)
Soldering Method
• Wave solder: 260°C, 10 Sec max.
• Infrared reflow: 260°C, 30 Sec max.
Specifications
Current
Voltage
Interrupting
DC Cold
Typical Typical
Product Code
Rating
Rating
Rating (amps)*
Resistance** (Ω) Melting Voltage
(amps)
AC DC 250Vac 125Vdc 60Vdc
Typical
I2t†
Drop‡
1025FA250-R
250mA
250V 125V 50
50
-
4.7500
0.1212 2019mV
1025FA500-R
500mA
250V 125V 50
50
-
1.1500
0.0415 1500mV
1025FA750-R
750mA
250V 125V 50
50
-
0.5550
0.143 880mV
1025FA1-R
1
250V 125V 50
50
-
0.2800
1.750 560mV
1025FA1.5-R
1.5
250V 125V 50
50
-
0.1140
1.460 260mV
1025FA2-R
2
250V 125V 50
50
-
0.0750
6.086 258mV
1025FA2.5-R
2.5
250V 125V 50
50
-
0.0510
8.48
232mV
1025FA3-R
3
250V 125V 50
50
-
0.0384
18.15 205mV
1025FA3.5-R
3.5
250V 125V 50
50
-
0.0305
17.83 185mV
1025FA4-R
4
250V 125V 50
50
-
0.0275
23.32 190mV
1025FA5-R
5
250V 125V 50
50
-
0.0195
38.74 180mV
1025FA7-R
7
250V 60V 50
-
50
0.0116
138
150mV
1025FA10-R
10
250V 60V 50
-
50
0.0072
457
146mV
1025FA12-R
12
250V 60V 50
-
50
0.0056
498
120mV
1025FA15-R
15
250V 60V 50
-
50
0.0039
1451 110mV
* AC interrupting rating (measured at designated voltage, 100% power factor random closing); DC interrupting rating (measured at designated voltage, time constant of
less than 50 microseconds, battery source)
** DC cold resistance (measured at ≤10% of rated current)
† Typical Melting I2t (measured with a battery bank at rated DC voltage, 10x-rated current, but not exceeding the interrupting rating. Time constant of calibrated circuit less
than 50 microseconds). Test current not to exceed interrupting rating of 50A.
‡ Typical voltage drop (measured at rated current after temperature stabilizes)
• Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at
elevated ambient temperatures.
0308 BU-SB08026
Page 1 of 2
Data Sheet 4322