English
Language : 

MSTM-S3-T2NC Datasheet, PDF (5/7 Pages) Connor-Winfield Corporation – STRATUM 3 SIMPLIFIED CONTROL TIMING MODULES
Fig. 7.0
THE CONNOR-WINFIELD CORP.
Stratum 3 Simplified Control
Timing Modules (MSTM-S3-T2NC)
5 VOLT DC
POWER
SUPPLY
BLOCK DIAGRAM
NE TW OR K
TIMING
RE FER ENC E
INPUT
eg. BITS CLOCK, etc.
FREE RUN
CLOCK COPY
SYSTEM CLOCK
+5Vdc
HOLDOVER
EX REF 1
REF 1
GND
REF 2
EX REF 2
FREERUN
GND
GND
CLK_OUT ALARM OUT
GND
CNTL A
SYNC_OUT
CNTL B
GND
PLL TVL
SYSTEM
CONTROL
AND DATA
INPUTS
LOSS OF
RE FER ENC E
MONITOR
SECTION
Fig 8.0
MECHANICAL CHARACTERISTICS
MECHANICAL SHOCK 883D 2002 CONDITION B
1500 G’s 0.5 ms.
VIBRATION 883D-2007 CONDITION A
0.06” DA or 20 g Peak Acceleration 20 to 2000 Hz
ENVIRONMENTAL CHARACTERISTICS
TEMPERATURE CYCLE 883D METHOD 1010.7 CONDITION B
10 Cycles –55 to +125 Degrees C.
HTOB - HIGH TEMPERATURE OPERATING BIAS
1000 Hours +125 Degrees C.
MSTM-S3
PACKAGE
WITH COVER
DATA SHEET #: TM020
DATE: 7/18/00
REVISION #: P00
Page 5 of 7
Specifications are subject to change without notice
FILENAME: TM020.DOC
Copyright 1999,2000 Connor-Winfield all rights reserved