TA7608_16 Datasheet, PDF (1/1 Pages) Coilcraft lnc. – Flyback Transformer | |||
|
Document 1274
Flyback Transformer For Silicon Labs Digital Isolators
with DC-DC Converter
⢠Developed for use with Silicon Labs Si88x2x Dual and Si88x4x Quad
ISOVolt isolated DC-DC-Converter reference designs
⢠Ultra-miniature flyback transformer, measures only 10.00 à 12.07 à 5.97 mm
⢠2500 Vrms isolation
⢠Low leakage inductance at 60 nH
⢠AEC-200 Grade 1 qualified (â40°C to +125°C ambient)
Core materialâFerrite
Terminationsâ RoHS tin-silver-copper (95.5/3.8/0.7) over tin over
nickel over phos bronze.
Weightâ 0.9 g
Ambient temperatureâ â40°C to +125°C
Maximum part temperatureâ +125°C (ambient + temp rise)
Storage temperatureâ Component: â40°C to +125°C.
Tape and reel packaging: â40°C to +80°C
Resistance to soldering heatâ Max three 40 second reflows at
+260°C, parts cooled to room temperature between cycles
Moisture Sensitivity Level (MSL)â 1 (unlimited floor life at <30°C /
85% relative humidity)
Failures in Time (FIT) / Mean Time Between Failures (MTBF)
38 per billion hours / 26,315,789 hours, calculated per Telcordia SR-332
Packagingâ 600 per 13â³ reelâ Plastic tape: 24 mm wide, 0.37 mm thick,
16 mm pocket spacing, 6.1 mm pocket depth
PCB washingâ Tested to MIL-STD-202 Method 215 plus an additional
aqueous wash. See Doc787_PCB_Washing.pdf.
Part
Input â Inductance2
â number1 voltage (V) ±5% (µH)
TA7608-AL_ 3.0 â 5.5
2.0
Leakage
â inductance3
max (µH)
0.06
DCR max
(Ohms)
Turns ratio âIsolation4 âIsat5
priâââ sec
priâ:âsec (Vrms) (A)
0.033 0.105
1â:â4
2500
4.25
Output
5 V, 0.4 A
1. When ordering, specify a packaging code:
TA7608-ALD
Packaging: D = 13â³ machine ready reel. EIA-481 embossed plastic
tape.
B = Less than full reel. In tape, but not machine ready.
To have a leader and trailer added ($25 charge), use
code letter D instead.
2. Inductance is for the primary, measured on an Agilent/HP 4284 at 100 kHz,
0.1 Vrms, 0 Adc.
3. Leakage inductance measured between pins 2 and 3 at 100 kHz, 0.1 Vrms,
0 Adc with pins 8 and 5 shorted.
4. Isolation (hipot) measured between windings for one minute.
5. DC current that causes an inductance drop of 30% (typ) from its value
without current
6. Electrical specifications at 25°C.
Refer to Doc 362 âSoldering Surface Mount Componentsâ before soldering.
2
Pri
3
8
Sec
5
4
0.394
10,00
max
1
0.475
12,07
max
0.028
5 0,70
0.079
2,00
8
Dot indicates pin 1
Internal code
0.235 max
5,97
0.067
1,70
0.358
9,1
0.004 / 0,10
0.063
1,60
0.079
2,00
1
8
Recommended
Land Pattern
Dimensions are in
inches
mm
US +1-847-639-6400 sales@coilcraft.com
UK +44-1236-730595 sales@coilcraft-europe.com
Taiwan +886-2-2264 3646 sales@coilcraft.com.tw
China +86-21-6218 8074 sales@coilcraft.com.cn
Singapore + 65-6484 8412 sales@coilcraft.com.sg
Document 1274â Revised 06/29/15
© Coilcraft Inc. 2016
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specification subject to change without notice.