AC-DC Power Supplies Open Frame/Enclosed type
Ordering information
LDC15F
LD C 15 F -1 -O
1
2
3
4
5
6
R
LDC
1Series name
2Multiple output
3Output wattage
4Universal input
5Output voltage combina-
tion
6Optional *4
C :with Coating
G :Low leakage current
S :with Chassis
SN :with Chassis & cover
Y :with Potentiometer
MODEL
DC OUTPUT
LDC15F-1
V1
+5V 2.0(Peak 3.0)A
V2
+12V 0.3(Peak 0.6)A
V3
-12V 0.2(Peak 0.3)A
LDC15F-2
+5V 2.0(Peak 3.0)A
+15V 0.3(Peak 0.6)A
-15V 0.2(Peak 0.3)A
SPECIFICATIONS
MODEL
LDC15F-1
LDC15F-2
VOLTAGE[V]
CURRENT[A]
AC85 - 264 1f or DC110 - 370
ACIN 100V 0.4typ (Io=100%)
FREQUENCY[Hz]
47 - 440 or DC
INPUT
EFFICIENCY[%] ACIN 100V 70typ (Io=100%)
ACIN 100V 25typ (Io=100%)
INRUSH CURRENT[A] ACIN 200V 50typ (Io=100%)
LEAKAGE CURRENT[mA] 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN)
VOLTAGE[V]
+5
+12
-12
+5
+15
-15
CURRENT[A]
*1 0 - 2.0 (Peak 3.0) 0 - 0.3 (Peak 0.6) 0 - 0.2 (Peak 0.3) 0 - 2.0 (Peak 3.0) 0 - 0.3 (Peak 0.6) 0 - 0.2 (Peak 0.3)
LINE REGULATION[mV] 20max
48max
48max
20max
60max
60max
LOAD REGULATION[mV] 100max
120max
120max
100max
150max
150max
RIPPLE[mVp-p]
0 to +50C*2 100max
-10 - 0C*2 140max
120max
160max
120max
160max
100max
140max
120max
160max
120max
160max
OUTPUT
RIPPLE NOISE[mVp-p] 0 to +50C*2 120max
-10 - 0C*2 160max
150max
180max
150max
180max
120max
160max
150max
180max
150max
180max
TEMPERATURE REGULATION[mV] 0 to +50C 50max
-10 to +50C 60max
350max
420max
350max
420max
50max
60max
350max
420max
350max
420max
DRIFT[mV]
START-UP TIME[ms]
*3 20max
xx
100max (ACIN 85V, Io=100%)
xx
20max
xx
xx
HOLD-UP TIME[ms]
10typ (ACIN 85V, Io=100%), 20typ (ACIN 100V, Io=100%), 100typ (ACIN 200V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
OUTPUT VOLTAGE SETTING[V] 4.9 to 5.3
11.4 to 12.6
-11.4 to -12.6
4.9 to 5.3
14.25 to 15.75 -14.25 to -15.75
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
PROTECTION OVERVOLTAGE PROTECTION Works over 115% of rating by zener diode clamping (+5V only)
CIRCUIT AND OPERATING INDICATION Not provided
OTHERS REMOTE SENSING
Not provided
REMOTE ON/OFF
Not provided
INPUT-OUTPUT
INPUT-FG
ISOLATION
OUTPUT-FG
OUTPUT-OUTPUT(V1-V2,V3)
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (At Room Temperature)
-10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet)
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet)
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY AND AGENCY APPROVALS
NOISE
REGULATIONS CONDUCTED NOISE
UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
OTHERS
CASE SIZE/WEIGHT
COOLING METHOD
50X26X127mm [1.97X1.02X5 inches] (WXHXD) /150g max (without chassis and cover)
Convection
*1 Peak load for 10sec. or less is acceptable if the total wattage is less than the rated wattage(-1: 16W, -2: 17.5W).When the load of +5V is OA, other output can be drawn by 80% of rated current.
*2 Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKU-GIKEN:RM101).
*3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output.
*4 Please contact us about safety approvals for the model with option.
* Avoid prolonged use under over-load.
* Derating is required when operated with chassis and cover.