English
Language : 

DA2077_13 Datasheet, PDF (1/1 Pages) Coilcraft lnc. – Flyback Transformer
Document 518
Flyback Transformer For ON Semiconductor
NCP1027
The DA2077-AL flyback transformer has been specifically
developed for use with ON Semiconductor’s NCP1027
Standby Power Supply for ATX Applications and is speci-
fied in Application Note AND8241/D.
This transformer is designed for universal input, 85 –
265 Vac. It operates in continuous conduction mode
within an input voltage range of 120 Vdc to 375 Vdc and
at a 65 kHz switching frequency. Primary to secondary
isolation is 2000 Vrms tested for one minute.
Coilcraft can also custom engineer a transformer to meet
your specific requirements. For free evaluation samples,
contact Coilcraft or visit www.coilcraft.com.
Part
number
Inductance Leakage
at 0 A1
DCR max (Ohms)  inductance2
±10% (mH)
pri
sec aux
max (µH)
 Turns ratio
pri : sec  pri : aux
DA2077-AL
3.4
2.53 0.042 0.574
114
1 : 0.06 1 : 0.15
1. Inductance is for the primary, measured at 10 kHz, 0.1 Vrms, 0 Adc
2. Leakage inductance tested at 100 kHz, 0.1 Vrms
3. Operating temperature range -40°C to +85°C.
4. Electrical specifications at 25°C.
Output
5 V, 2 A (sec)
12.5 V, 10 mA (aux)
1.100
27,94
max
10
Primary
5
Secondary
0.950 max
24,13
6
1
7
Auxiliary
9
0.620
15,75
0.150 ±0.030
3,81 ±0,76
Recommended
0.150 Board Layout
3,81
5
6
1
1.100
27,94
max
0.200
5,08
(7
places)
1
10
0.0346
0,879
Bottom View
0.620
15,75
0.060
1,52
Weight:
16.5 g
Terminations: Matte tin over copper
Packaged: 49 parts per tray
US +1-847-639-6400 sales@coilcraft.com
UK +44-1236-730595 sales@coilcraft-europe.com
Taiwan +886-2-2264 3646 sales@coilcraft.com.tw
China +86-21-6218 8074 sales@coilcraft.com.cn
Singapore + 65-6484 8412 sales@coilcraft.com.sg
Document 518  Revised 12/02/08
© Coilcraft Inc. 2013
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specification subject to change without notice.
Please check web site for latest information.