CS60-050L_16 Datasheet, PDF (1/1 Pages) Coilcraft lnc. – 50/60 Hz Current Sensor
Document 134
50/60 Hz Current Sensor  CS60-010
The CS60 series is designed to measure current from 5
to 100 Arms. Applications include sensing branch circuit
overload and detecting load drop or shutdown. The sen-
sor functions as the encapsulated secondary of a current
transformer, while the conductor carrying the current to
be measured serves as the “one turn primary.” Sensitivity
may be enhanced by increasing primary turns.
These parts are mountable on printed circuits and have a
third terminal added for mechanical stability.
Samples of these and other current sensors are available
for evaluation. To request samples, contact Coilcraft or visit
www.coilcraft.com.
Typical Response
Current (A rms)
Typical Circuit
Irms
Part
number
CS60-050L
CS60-075L
CS60-100L
Sensed
current (Irms)
5-50 A rms
5-75 A rms
5-100 A rms
Vout
tolerance
±10%
±10%
±10%
(For sensed current below 10 A rms, see CS60-010 data sheet)
1. Ambient temperature range –40°C to +85°C.
2. Electrical specifications at 25°C.
Weight  13.8 – 15.4 g
Terminations  Tin-silver over copper
Packaging  30 per tray
0.350 min
8,89
CS60-0xxL
XXXXY
Parts manufactured
prior to February, 2012
may be marked
differently.
Part number
Internal code
1.25 max
31,75
0.600 ±0.010
15,24 ±0,254
0.042
1,07
±0.002
±0,05
dia
0.250 ±0.010
6,35 ±0,254
0.150 ±0.030
3,81 ±0,762
4 1 2 (N.C.)
1
2
(N.C.)
0.750
19,05
max
4
220⏲
Vout rms
1.10 max
27,94
Dimensions are in
inches
mm
US +1-847-639-6400 sales@coilcraft.com
UK +44-1236-730595 sales@coilcraft-europe.com
Taiwan +886-2-2264 3646 sales@coilcraft.com.tw
China +86-21-6218 8074 sales@coilcraft.com.cn
Singapore + 65-6484 8412 sales@coilcraft.com.sg
Document 134  Revised 02/22/12
© Coilcraft Inc. 2016
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specification subject to change without notice.
Please check web site for latest information.