CS2106L_15 Datasheet, PDF (1/1 Pages) Coilcraft lnc. – 50/60 Hz Current Sense Transformer
Document 150
50/60 Hz Current Sense Transformer
This Coilcraft current sense transformer is intended for
use in measuring 50/60 Hz line currents from 0.5 to
20 Amperes rms. Typical application shown below yields
an output of 0.1 Volt per Ampere. The sensitivity may be
changed by adjusting the value of the terminating resis-
tance (RT). These parts also can be used to measure
400 Hz line currents.
To request free evaluation samples, contact Coilcraft or
visit www.coilcraft.com.
Weight  19 g
Terminations  Tin-silver over tin over nickel over copper
Packaging  30 per tray
Isolation (hipot)  2500 Vrms, one minute, between windings
Moisture Sensitivity Level (MSL)  1 (unlimited floor life at <30°C /
85% relative humidity)
Failures in Time (FIT) / Mean Time Between Failures (MTBF)
38 per billion hours / 26,315,789 hours, calculated per Telcordia SR-332
PCB washing  Tested to MIL-STD-202 Method 215 plus an additional
aqueous wash. See Doc787_PCB_Washing.pdf
Frequency
Part
Turns (N)   Inductance1
DCR max (Ohms)
  range2
number
pri : sec
min (mH)
1,2 – 3,4   8 – 5
(Hz)
CS2106L
1 : 500
75
0.007
26
50 – 400
Sensed
current
range Iin
0.5 A – 20 A
RT for
1.0 Vout
  from 10 A Iin3
68 Ohms
1. Inductance is for the secondary, tested at 1 kHz, 0.1 Vrms.
2. Square wave response deteriorates above and below this frequency.
3. Use the following equation to determine the approximate change in output voltage/ input ampere when varying the terminating resistor:
Vout / Iin = 0.1 × (RT / 68).
4. Ambient temperature range –40°C to +85°C.
5. Electrical specifications at 25°C.
Typical Circuit
1
8
2
I in
CS2106
RT Vout
3
4
5
Typical Response (with RT = 68 Ohms)
2.0
1.5
1.0
0.5
0
0
5
10
15
20
Current (Amperes rms)
Dimensions are in
inches
mm
Document 150  Revised 12/29/09