English
Language : 

CS2106L Datasheet, PDF (1/1 Pages) Coilcraft lnc. – 50/60 Hz Current Sensing Transforme
Document 150
50/60 Hz Current Sensing Transformer
This Coilcraft current sense transformer is intended for
use in measuring 50/60 Hz line currents from 0.5 to
20 Amperes rms. Typical application shown below yields
an output of 0.1 Volt per Ampere. The sensitivity may
be changed by adjusting the value of the terminating
resistance (RT). These parts also can be used to mea-
sure 400 Hz line currents.
To request free evaluation samples, contact Coilcraft
or visit www.coilcraft.com.
Part
number
CS2106L
Turns (N)
pri : sec
1 : 500
Inductance1
min (mH)
75
DCR max (Ohms)
1,2 – 3,4 8 – 5
0.007
26
Frequency
range2
(Hz)
50 – 400
Sensed
current
range Iin
0.5 A – 20 A
1. Inductance is for the secondary, tested at 1 kHz, 0.1 Vrms.
2. Square wave response deteriorates above and below this frequency.
3. Varying terminating resistance increases or decreases output Voltage/Ampere in approximate proportion to the ratio RT / 68.
4. Operating temperature range –40°C to +85°C.
5. Electrical specifications at 25°C.
Typical Circuit
RT for
1.0 Vout
from 10 A Iin3
68 Ohms
1
8
2
I in
CS2106
RT Vout
3
4
5
Typical Response (with RT = 68 Ohms)
2.0
1.5
1.0
0.5
0
0
5
10
15
Current (Amperes rms)
20
Weight:
19 g
Terminations: Tin-silver over copper
Packaging: 30 per tray
Specifications subject to change without notice.
Please check our website for latest information.
Document 150 Revised 12/29/09