0805 COMMON MODE CHOKES
Common Mode Chokes for Critical Applications
• Eliminates virtually all common mode noise in high-speed,
differential mode signal transmission applications such as
USB 2.0, IEEE1394, HDMI and LVDS.
• Most provide >25 dB common mode attenuation and
>100 ohms impedance.
Core material Ferrite
Terminations  Gold over nickel over silver-palladium-glass frit. Other
terminations available at additional cost
Weight  14.9 – 15.2 mg
Ambient temperature  –40°C to +85°C with Irms current, +85°C to
+105°C with derated current
Storage temperature  Component: –55°C to +105°C.
Tape and reel packaging: –55°C to +80°C
Resistance to soldering heat  Max three 40 second reflows at
+260°C, parts cooled to room temperature between cycles
Moisture Sensitivity Level (MSL)  1 (unlimited floor life at <30°C /
85% relative humidity)
Packaging  2000 per 7″reel;  Plastic tape:  8 mm wide, 0.23 mm thick,
4 mm pocket spacing, 1.14 mm pocket depth
Part number1
CP336FRA421MAZ
CP336FRA901MAZ
CP336FRA172MAZ
CP336FRA262MAZ
CP336FRA372MAZ
CP336FRA502MAZ
CP336FRA672MAZ
CP336FRA902MAZ
Common mode
impedance typ (Ohms)
10 MHz 100 MHz 500 MHz
14
42
70
28
90
154
57
170
303
85
260
435
118
370
641
148
500
945
246
670 1231
294
900 1715
Common mode
attenuation typ (dB)
  Inductance2   DCR max3 Isolation  Irms4
10 MHz 100 MHz 500 MHz min (nH) (Ohms) (Vrms) (mA)
1.1
2.3
8.4
23
1.4
4.2 16.9
47
2.3
6.7 22.0
84
3.0
8.6 27.8
147
4.5 11.9 34.3
189
0.12
250 500
0.17
250 500
0.25
250 500
0.26
250 500
0.32
250 500
4.9 14.5 31.3
273
8.4 16.6 30.0
322
8.7 18.7 30.5
413
0.37
250 500
0.45
250 500
0.65
250 250
1. When ordering, please specify termination and testing codes:
CP336FRA902MAZ
Termination: A = RoHS compliant gold over nickel over silver-
palladium-glass frit
Special order:
C = Tin-lead over gold over nickel over silver-palladium-
glass frit
F = Tin-silver-copper over gold over nickel over silver-
palladium-glass frit
Testing: Z = COTS
H = Screening per Coilcraft CP-SA-10001
2. Inductance measured at 100 MHz using an Agilent/HP 4286A
impedance analyzer and a Coilcraft SMD-A fixture.
3. DCR is specified per winding.
4. Current per winding that causes a 20°C rise from 25°C ambient.
5. Electrical specifications at 25°C.
Refer to Doc 362 “Soldering Surface Mount Components” before soldering.
02.0,2990max
0.065
1,65
max
0.020 0.040
0,51 1,02
0.004
0,10
1
2
01.0,7638max
4
3
0.018
0,46
Dimensions are
in
inches
mm
1
2
4
3
0.030 0.036
0,76 0,91
2
0.014
1 0,36
3
4
Recommended
Land Pattern
0.020
0,51
© Coilcraft, Inc. 2012
®
ThDisopcruodmuectnmt CayPn3o0t 6b-e1u seRdeinvimseeddic0a9l /o0r7h/i1g2h
1102 Silver Lake Road
Fax 847-639-1508
risk applications without prior Coilcraft approval.
Cary, IL 60013
Email cps@coilcraft.com Specifications subject to change without notice.
Phone 800-981-0363
www.coilcraft-cps.com
Please check our web site for latest information.