1.6.1.10 DTMF Answerback Code
The DTMF answerback code may be selected by an appropriate choice of the four jumpers JP9.
Fitting a jumper sets that input to logic '0'. If not fitted, the input is pulled-up on-chip to logic '1'.
Alternatively, all of the JP9 jumpers may be omitted and the DTMF generator may be driven from a µ
C. A logic '1' on TX-DTMF (J1 pin 5) enables the generator and illuminates the LED.
DTMF GENERATOR DECODE TABLE
J1:9 (D3)
J1:10 (D2) J1:11 (D1)
0
0
0
0
0
0
0
0
1
0
0
1
0
1
0
0
1
0
0
1
1
0
1
1
1
0
0
1
0
0
1
0
1
1
0
1
1
1
0
1
1
0
1
1
1
1
1
1
J1:12 (D0)
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
DTMF
CODE
D
1
2
3
4
5
6
7
8
9
0
#
A
B
C
1.6.1.11 Line Impedance Matching
Line impedance matching is provided by R20, which is not fitted. A resistor (value ≈ 600Ω) is required
for the evaluation board to operate correctly.
1.6.1.12 Voice Mute
A mutable local voice input is provided on test point TP18. A logic '1' on 604-RXEQ (J1 pin 20)
unmutes the voice input, selects the FX604 equalisation and illuminates the LED. Access to voice
signals is provided as follows:
The hybrid receive output (Rx = remote voice) is located on test point TP16.
The hybrid transmit output (Tx = local voice) is located on test point TP15.
If a voice input is not required, test point TP18 should be connected to ground.
1.6.1.13 Evaluation Device FX602/FX604/FX614
If the evaluation device is an FX602 it should be fitted in socket U2 position 1 and jumper JP10 should
be fitted. If the evaluation device is an FX604 or FX614 it should be fitted in socket U2 position 2 and
jumper JP10 should be removed, thus disabling the parallel phone detector output. This output is still
available on test point TP17.
Figure 4 FX604 Configuration
© 1996 Consumer Microcircuits Limited
11
UM6040/3