English
Language : 

INV8 Datasheet, PDF (1/1 Pages) Chicago Miniature Lamp,inc – Cold Cathode Lamp Inverter Drive module
Type
Cold Cathode Lamp Inverter Drive module
Part No.
INV 8 (OA-6012-0505D)
12VDC input
Connector system
JST XHP-2
-- +
TR1
L1
C1 R1
T1
R2
TR2
C3
C4
CCFL output
Connector system
JST XHP-3
L75 x W25 x H15
Drawing not to scale
All dimensions in mm
CHARACTERISTIC DATA
Dual Output suitable for CCFL length:
Input Voltage
Input Current
No Load Output Voltage
Lamp Output Voltage (VL)
Nominal Drive current (IL)
Operating frequency (f)
Operating temperature
Operating humidity
Operating life
300 ~ 420 mm
12VDC ± 1.5V
900 mA maximum
1200V rms minimum, 1400V rms nominal
1000V rms nominal
12 mA ± 1mA (6mA per output)
28 ± 5 kHz
0 ~ 50 ºC
5 ~ 70% RH
20,000 hours @ 13.2VDC
NOTES:
1. The inverter module should be protected from moisture, condensation and freezing.
2. Suitable screening may be necessary for electromagnetic compatibility and protection.
3. The use of silicone rubber stranded wire is recommended for connecting the CFFL.
4. Danger of electric shock.