English
Language : 

CPC7595_1 Datasheet, PDF (8/24 Pages) Clare, Inc. – Line Card Access Switch
CPC7595
1.6.4 TESTout Switches, SW5 and SW6
Parameter
Test Conditions
Symbol Minimum Typical Maximum
Unit
VSW5 (differential) = TLINE to TTESTOUT
VSW6 (differential) = RLINE to RTESTOUT
All-Off state.
+25° C,
VSW (differential) = -320 V to gnd
Off-State
VSW (differential) = +260 V to -60 V
Leakage Current
+85° C
VSW (differential) = -330 V to gnd
ISW
-
VSW (differential) = +260 V to -60 V
-40° C
VSW (differential) = -310 V to gnd
VSW (differential) = +250 V to -60 V
ISW (on) = ±10 mA, ±40 mA
On Resistance
+25° C
+85° C
RON
-
-40° C
0.1
0.3
1
μA
0.1
35
-
50
70
Ω
26
-
DC current limit
VSW (on) = ±10 V
+25° C
+85° C
-40° C
-
140
-
ISW
80
100
-
mA
-
210
250
Dynamic current limit
(t ≤ 0.5 μs)
Test out switches on, all other switches
off. Apply ±1 kV, 10x1000 μs pulse with
appropriate protection in place.
ISW
-
2.5
-
A
VSW5 (TTESTout, TLINE)
VSW6 (RTESTout, RLINE)
Logic input to switch Logic inputs = GND
output isolation
+25° C, VSW = ±320 V
0.1
+85° C, VSW = ±330 V
ISW
-
0.3
1
μA
-40° C, VSW = ±310 V
0.1
dv/dt sensitivity
100VPP Square Wave, 100Hz
(Not production tested - limits are
-
guaranteed by design and quality
control sampling audits.)
500
-
V/μs
8
www.clare.com
R02