English
Language : 

CPC5710N_1 Datasheet, PDF (4/10 Pages) Clare, Inc. – Phone Line Monitor (PLM) IC
CPC5710N
1.5 Electrical Characteristics
Unless otherwise specified, minimum and maximum
values are guaranteed by production testing
requirements. Typical values, the result of engineering
evaluations, are characteristic of the device and are
provided for informational purposes only. They are not
however, a part of the production testing requirements.
Unless otherwise indicated:
VDD = 5V, Temperature = 25°C
1.5.1 AC Characteristics
Parameter
Symbol
Conditions
Input Impedance
Input offset voltage
Input offset current
Output DC bias level
Output Low Voltage
Gain
Common-mode
rejection ratio
Equivalent input noise
voltage
ZIN
VIO
ICM = 0, No common-mode signal applied.
IIO
ICM = 12µA (per lead) signal applied.
VOUT_DC At LINOUT+ or LINOUT-, IO = 0.5mA
VOUT IO = 0.5mA
AV 0 to 20kHz
CMRR Common-mode current ≤ 12µA per lead,
0 to 120Hz
VN
Minimum Typical Maximum Unit
10
-
-
MΩ
-
-
40
mV
-
-
35
nA
-
-
125
nA
0.9
1.0
1.1
V
-
-
50
mV
5.88
6
6.12
-
40
-
-
dB
-
-90
-
dBm/Hz
1.5.2 Detector Threshold Characteristics
Parameter
Symbol
Conditions
Detection threshold
Detector hysteresis
ICM = 0
VIN_DET
ICM = ±12µA
VIN_HYST ICM = 0
Minimum Typical Maximum Unit
675
750
850
mV
488
750
1012
mV
300
375
450
mV
1.5.3 LIN/CMP Input Characteristics
Parameter
Symbol
Input low voltage
Input high voltage
Input low leakage
current
Input high leakage
current
VIL
VIH
IIL VIL = 0.4V
IIH VIH = 2.4V
Conditions
Minimum Typical Maximum Unit
-
-
0.8
V
2.0
-
-
V
-
-
-120
µA
-
-
-120
µA
1.5.4 Power Characteristics
Parameter
Symbol
Conditions
Supply voltage
Supply current
VDD
IDD All inputs and outputs open
4
www.clare.com
Minimum Typical Maximum Unit
3.0
-
5.5
V
-
-
10
mA
R02