PERFORMANCE DATA*
PLA190
Typical LED Forward Voltage Drop
(N=50 Ambient Temperature = 25°C)
IF = 5mADC
35
30
25
20
15
10
5
0
1.17
1.19
1.21
1.23
1.25
LED Forward Voltage Drop (V)
PLA190
Typical IF for Switch Operation
(N=50 Ambient Temperature = 25°C)
(Load Current = 150mADC)
25
20
15
10
5
0
0.75
1.05
1.35
1.65
1.95
2.25
LED Current (mA)
PLA190
Typical Turn-On Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 100mADC; IF = 5mADC)
25
20
15
10
5
0
0.23
0.26
0.29
0.32
0.35
Turn-Off (ms)
0.38
PLA190
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25°C)
(Load Current = 150mADC; IF = 5mADC)
!#
!
#

#

#

# $ % & '

On-Resistance (Ω)
PLA190
Typical IF for Switch Dropout
(N=50 Ambient Temperature = 25°C)
25
20
15
10
5
0
0.75
1.05
1.35
1.65
1.95
2.25
LED Current (mA)
PLA190
Typical Load Current vs. Temperature
300
250
DC Configuration
200
150
AC/DC Configuration
100
50
10mA
5mA
10mA
5mA
0
-40 -20 0 20 40 60 80 100 120
Temperature (°C)
PLA190
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25°C)
35
30
25
20
15
10
5
0
441.5 450.5 459.5 468.5 477.5 486.5
Blocking Voltage (V)
PLA190
Typical Turn-On Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 100mADC; IF = 5mADC)
25
20
15
10
5
0
0.23
0.26
0.29
0.32
0.35
Turn-Off (ms)
0.38
PLA190
Typical On-Resistance vs. Temperature
(Load Current = Max Rated at Temp.)
DC Configuration
10
9
IF=5mA
8
7
IF=10mA
6
5
0
-40 -20
0
20
40
60
80 100
PLA190
Typical On-Resistance vs. Temperature
(Load Current = Max rated at Temp.)
AC/DC Configuration
25
5mA
20
10mA
15
10
5
0
-40 -20
0
20
40
60
80 100
PLA190
Typical On Resistance vs. Temp.
Load Current=100mA Instantaneous
25
20
IF=5mA
15
10
5
-40 -20
0
20 40 60 80 100 120
Temperature (°C)
0.035
PLLAA119100
Typical Leakage vs. Temperature
(Measured across Pins 4 & 6)
0.030
0.025
0.020
0.015
0.010
0.005
0
-40
-20
0
20
40
60
Temperature (°C)
80 100
The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact