LCA710
PERFORMANCE DATA*
LCA710
Typical LED Forward Voltage Drop
(N=50 Ambient Temperature = 25°C)
IF = 10mADC
35
30
25
20
15
10
5
0
1.17
1.19 1.21 1.23 1.25
LED Forward Voltage (V)
LCA710
Typical IF for Switch Operation
(N=50 Ambient Temperature = 25°C)
(Load Current = 1ADC)
25
20
15
10
5
0
1.25 1.75 2.25 2.75 3.25 3.75
LED Current (mA)
LCA710
Typical Turn-Off Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 1ADC; IF = 10mADC)
25
20
15
10
5
0
0.03 0.05 0.07 0.09 0.11 0.13
Turn-Off (ms)
LCA710
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25°C)
(Load Current = 1ADC; IF = 10mADC)
35
30
25
20
15
10
5
0
0.215 0.225 0.235 0.245 0.255 0.265
On-Resistance (Ω)
LCA710
Typical IF for Switch Dropout
(N=50 Ambient Temperature = 25°C)
(Load Current = 1ADC)
25
20
15
10
5
0
1.25 1.75 2.25 2.75 3.25 3.75
LED Current (mA)
LCA710
Typical Load Current vs. Temperature
1800
1600
1400
1200
1000
800
600
400
-40 -20
20mA
10mA
5mA
0 20 40 60 80 100 120
Temperature (°C)
LCA710
Typical Blocking Voltage vs. Temperature
81.0
80.0
79.0
78.0
77.0
76.0
75.0
74.0
73.0
-40 -20 0
20 40 60
80 100
Temperature (°C)
1.400
LCA710
Typical Turn-On vs. Temperature
(Load Current = 1ADC)
1.200
1.000
10mA
0.800
0.600
20mA
0.400
0.200
0
-40 -20
0 20 40 60
Temperature (°C)
80 100
LCA710
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25°C)
35
30
25
20
15
10
5
0
72 74 76 78 80 82
Blocking Voltage (V)
LCA710
Typical Turn-On Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 1ADC; IF = 10mADC)
25
20
15
10
5
0
0.5 0.7 0.9 1.1 1.3 1.5
Turn-On (ms)
0.007
LCA710
Typical Leakage vs. Temperature
(Measured across Pins 4 & 6)
0.006
0.005
0.004
0.003
0.002
0.001
0
-40 -20
0 20 40 60
Temperature (°C)
80 100
0.140
LCA710
Typical Turn-Off vs. Temperature
(Load Current = 1ADC)
0.120
0.100
0.080
0.060
0.040
0.020
10mA
0
-40 -20
0 20 40 60
Temperature (°C)
80 100
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact