English
Language : 

LCA220 Datasheet, PDF (3/6 Pages) Clare, Inc. – Commom Input OptoMOS Relays
PERFORMANCE DATA*
LCA220
LCA220
Typical LED Forward Voltage Drop
(N=50 Ambient Temperature = 25°C)
IF = 10mADC
35
30
25
20
15
10
5
0
1.17
1.19
1.21
1.23
1.25
LED Forward Voltage Drop (V)
LCA220
Typical IF for Switch Operation
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC)
25
20
15
10
5
0
0.60
0.84
1.08
1.32
1.56
1.80
LED Current (mA)
LCA220
Typical Turn-Off Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC; IF = 10mADC)
25
20
15
10
5
0
0.20 0.30 0.40 0.50 0.60 0.70 0.80
Turn-Off (ms)
LCA220
Typical Blocking Voltage
vs. Temperature
340
335
330
325
320
315
310
305-40 -20 0 20 40 60 80 100
Temperature (°C)
LCA220
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC; IF = 10mADC)
30
25
20
15
10
5
0
8.25
12.5
12.7
12.9
On-Resistance (Ω)
10.25
LCA220
Typical IF for Switch Dropout
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC)
25
20
15
10
5
0
0.50
0.60
0.70
0.80
0.90
1.0
LED Current (mA)
LCA220
Typical Load Current vs. Temperature
200
175
150
125
100
20mA
75
10mA
0
-40 -20 0 20 40 60 80 100 120
Temperature (°C)
LCA220
Typical Turn-On vs. Temperature
(Load Current = 80mADC)
3.0
2.5
10mA
2.0
1.5
20mA
1.0
0.5
0-40 -20
0 20 40 60
Temperature (°C)
80 100
LCA220
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25°C)
#

#

#

!' " " "  "! ""
Blocking Voltage (V)
LCA220
Typical Turn-On Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC; IF = 10mADC)
25
20
15
10
5
0
1.6
1.7
1.8
1.9
2.0
2.1
2.2
Turn-On (ms)
LCA220
Typical Leakage vs. Temperature
(Measured across Pins 5 & 6 or 7 & 8)
0.100
0.090
0.080
0.070
0.060
0.050
0.040
0.030
0.020
0.010
0
-40 -20 0 20 40 60 80 100
Temperature (°C)
LCA220
Typical Turn-Off vs. Temperature
(Load Current = 80mADC)
0.60
0.50
0.40
0.30
0.20
0.10
0
10mA
-40 -20 0 20 40 60 80 100
Temperature (°C)
The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact
our application department.
Rev. 6
www.clare.com
3