PERFORMANCE DATA*
LCA110
Typical LED Forward Voltage Drop
(N=50 Ambient Temperature = 25°C)
IF = 5mADC
35
30
25
20
15
10
5
0
1.17 1.19 1.21 1.23 1.25
LED Forward Voltage Drop (V)
LCA110
Typical IF for Switch Operation
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC)
25
20
15
10
5
0
0.39 0.65 0.91 1.17 1.43 1.69 1.95
LED Current (mA)
LCA110
Typical Turn-Off Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC; IF = 2mADC)
25
20
15
10
5
0
0.175 0.245 0.315 0.385 0.455 0.525 0.595
Turn-Off (ms)
LCA110
Typical Blocking Voltage
vs. Temperature
430
425
420
415
410
405
400
395
-40 -20
0 20 40 60
Temperature (°C)
80 100
LCA110
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC)
35
30
25
20
15
10
5
0
23 23.4 23.8 24.2 24.6 25.0 25.4
On-Resistance (Ω)
LCA110
Typical IF for Switch Dropout
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC)
25
20
15
10
5
0
0.39 0.65 0.91 1.17 1.43 1.69 1.95
LED Current (mA)
LCA110
Typical Load Current vs. Temperature
210
DC Configuration
200
180
160
10mA
140
5mA
120
100
AC/DC Configuration
80
60
10mA
5mA
0
-40 -20 0 20 40 60 80 100 120
Temperature (°C)
5.000
LCA110
Typical Turn-On vs. Temperature
(Load Current = 70mADC)
4.500
4.000
3.500
3.000
2.500
2.000
1.500
1.000
5mA
10mA
0.500
0
-40 -20 0
20 40 60
20mA
80 100
Temperature (°C)
LCA110
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25°C)
35
30
25
20
15
10
5
0
390 400 410 420 430 440 450
Blocking Voltage (V)
LCA110
Typical Turn-On Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC; IF = 2mADC)
25
20
15
10
5
0
0.15 0.45 0.75 1.05 1.35 1.65 1.95
Turn-On (ms)
0.016
LCA110
Typical Leakage vs. Temperature
(Measured across Pins 4 & 6)
0.014
0.012
0.010
0.008
0.006
0.004
0.002
0
-40 -20 0
20 40 60
80 100
Temperature (°C)
LCA110
Typical Turn-Off vs. Temperature
(Load Current = 70mADC)
1.000
0.900
0.800
0.700
0.600
0.500
0.400
0.300
0.200
0.100
5mA
0
-40 -20 0
20 40 60
80 100
Temperature (°C)
The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact