English
Language : 

LCA100 Datasheet, PDF (3/6 Pages) Clare, Inc. – Single Pole OptoMOS Relay
LCA100
PERFORMANCE DATA*
LCA100
Typical LED Forward Voltage Drop
(N=50 Ambient Temperature = 25°C)
IF = 5mADC
35
30
25
20
15
10
5
0
1.17 1.19 1.21 1.23 1.25
LED Forward Voltage Drop (V)
LCA100
Typical IF for Switch Operation
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC)
25
20
15
10
5
0
0.85 0.90 0.95 1.00 1.05 1.10 1.15
LED Current (mA)
LCA100
Typical Turn-Off Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC; IF = 5mADC)
25
20
15
10
5
0
0.06 0.08 0.10 0.13 0.15 0.17 0.19
Turn-Off (ms)
LCA100
Typical Blocking Voltage
vs. Temperature
410
405
400
395
390
385
380
375
-40 -20
0 20 40 60
Temperature (°C)
80 100
LCA100
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC)
35
30
25
20
15
10
5
0
13.93 14.05 14.17 14.29 14.41 14.54 14.66
On-Resistance (Ω)
LCA100
Typical IF for Switch Dropout
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC)
25
20
15
10
5
0
0.85 0.90 0.95 1.00 1.05 1.10 1.15
LED Current (mA)
LCA100
Typical Load Current vs. Temperature
180
160
140
120
100
80
20mA
10mA
60
5mA
40
20
0
-40 -20 0 20 40 60 80 100 120
Temperature (°C)
3.000
LCA100
Typical Turn-On vs. Temperature
(Load Current = 120mADC)
2.500
2.000
5mA
1.500
1.000
10mA
20mA
0.500
0
-40 -20
0 20 40 60 80 100 120
Temperature (°C)
LCA100
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25°C)
35
30
25
20
15
10
5
0
369.8 374.6 379.4 384.1 388.9 393.7 398.4
Blocking Voltage (V)
LCA100
Typical Turn-On Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC; IF = 5mADC)
25
20
15
10
5
0
1.72 1.87 2.02 2.17 2.32 2.46 2.61
Turn-On (ms)
0.016
LCA100
Typical Leakage vs. Temperature
(Measured across Pins 4 & 6)
0.014
0.012
0.010
0.008
0.006
0.004
0.002
0
-40 -20 0
20 40 60
80 100
Temperature (°C)
LCA100
Typical Turn-Off vs. Temperature
(Load Current = 100mADC)
0.50
0.45
0.40
0.35
0.30
0.25
0.20
0.15
0.10
0.05
0
-40 -20 0 20 40 60 80 100 120
Temperature (°C)
The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact
our application department.
Rev. 1
www.clare.com
3