English
Language : 

CPC7557 Datasheet, PDF (3/5 Pages) Clare, Inc. – Diode Bridge
CPC7557
1.4 Recommended Operating Conditions
Parameter
Diode Forward Current (Average)
Reverse Voltage
Operating Temperature Range
Thermal Impedance
Symbol
IF
VR
TA
JA
Minimum
-
-
-40
120
Maximum
240
100
+125
-
Units
mArms
V
C
C/W
1.5 General Conditions
Typical values are characteristic of the device at 25C
and are the result of engineering evaluations. They are
provided for information purposes only and are not
part of the manufacturing testing requirements.
Unless otherwise noted, all electrical specifications
are listed for TA=25C.
1.6 DC Electrical Characteristics
Parameter
Forward Current
Diode Forward Voltage Drop
Reverse Voltage Leakage Current
Conditions
-
IF = 40mA
IF = 250mA
VR=100V
Symbol
IF
VF
IR
Minimum
-
0.83
1
-
Typical
-
0.91
1.3
-
Maximum
240
0.97
1.49
1
Units
mArms
V
A
1.7 AC Electrical Characteristics
Parameter
Input Zero Bias Capacitance
Output Zero Bias Capacitance
Bridge Zero Bias Capacitance
Conditions
V+  V = 0V
Measured from VA to VB
VA = VB
Measured from V+ to V
V+  V = 0V Measured from
VA to V+/- and VB to V+/-
Symbol
CAB
Minimum Typical Maximum Units
-
4.4
12
pF
C+/
-
CA/+, CA/,
CB/+, CB/
-
8.3
20
pF
8.5
12
pF
2 Typical Performance Data
2.8
2.6
2.4
2.2
2.0
1.8
1.6
1.4
1.2
1.0
-40
Bridge Forward Voltage (VF)
vs. Temperature
IF=250mA
IF=40mA
-20 0 20 40 60 80 100
Temperature (ºC)
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
-40
Diode Forward Voltage (VF)
vs. Temperature
IF=250mA
IF=40mA
-20 0 20 40 60 80 100
Temperature (ºC)
Diode Reverse Breakdown Voltage (VRRM)
vs. Temperature
152
150
148
146
144
142
140
138
-40 -20
0 20 40 60
Temperature (ºC)
80 100
3
www.clare.com
R02