English
Language : 

PAA110 Datasheet, PDF (2/7 Pages) Clare, Inc. – Single Pole OptoMOS Relays
PAA110
Absolute Maximum Ratings (@ 25˚ C)
Parameter
Input Power Dissipation
Input Control Current
Peak (10ms)
Reverse Input Voltage
Total Power Dissipation
Isolation Voltage
Input to Output
Operational Temperature
Storage Temperature
Soldering Temperature
DIP Package
Flatpack/Surface Mount
Package
(10 Seconds Max.)
1 Derate Linearly 1.33 mw/˚C
2 Derate Linearly 6.67 mw/˚C
Min Typ Max Units
-
- 1501 mW
-
- 50 mA
-
-1 A
-
-5 V
-
- 8002 mW
3750
-40
-40
-
- VRMS
- +85 °C
- +125 °C
-
- +260 °C
-
- +220 °C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at these or
any other conditions beyond those indicated in the opera-
tional sections of this data sheet is not implied. Exposure of
the device to the absolute maximum ratings for an extend-
ed period may degrade the device and effect its reliability.
Electrical Characteristics
Parameter
Conditions
Symbol Min Typ
Output Characteristics @ 25°C
Load Voltage (Peak)
-
VL
Load Current* (Continuous)
AC/DC Configuration
-
IL
Peak Load Current
10ms
ILPK
On-Resistance
AC/DC Configuration
IL=150mA
RON
Off-State Leakage Current
VL=400V
ILEAK
Switching Speeds
Turn-On
IF=5mA, VL=10V
TON
Turn-Off
IF=5mA, VL=10V
TOFF
Output Capacitance
50V; f=1MHz
COUT
Load Current Limiting
ICL
Input Characteristics @ 25°C
-
-
-
-
-
-
-
15
-
-
-
-
-
-
-
25
-
-
Input Control Current
Input Dropout Current
Input Voltage Drop
Reverse Input Voltage
Reverse Input Current
Input to Output Capacitance
Input to Output Isolation
IL=150mA
-
IF=5mA
-
VR=5V
-
-
IF
5
-
IF
0.4
0.7
VF
0.9
1.2
VR
-
-
IR
-
-
CI/O
-
3
VI/O
3750
-
*NOTE: If both poles operate simultaneously load current must be derated so as not to exceed the package power dissipation value.
Max Units
400 V
150 mA
400 mA
22
Ω
1
µA
1
ms
0.25 ms
-
pF
-
mA
50 mA
-
mA
1.4
V
5
V
10 µA
-
pF
-
VRMS
2
www.clare.com