English
Language : 

LCA120 Datasheet, PDF (2/6 Pages) Clare, Inc. – Single Pole OptoMOS Relay
LCA120
Absolute Maximum Ratings (@ 25˚ C)
Parameter
Input Power Dissipation
Input Control Current
Peak (10ms)
Reverse Input Voltage
Total Power Dissipation
Isolation Voltage
Input to Output
Operational Temperature
Storage Temperature
Soldering Temperature
DIP Package
Surface Mount Package
(10 Seconds Max.)
1 Derate Linearly 1.33 mw/˚C
2 Derate Linearly 6.67 mw/˚C
Min Typ Max Units
-
- 1501 mW
-
- 50 mA
-
-1 A
-
-5 V
-
- 8002 mW
3750
-40
-40
-
- VRMS
- +85 °C
- +125 °C
-
- +260 °C
-
- +220 °C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at these or
any other conditions beyond those indicated in the opera-
tional sections of this data sheet is not implied. Exposure of
the device to the absolute maximum ratings for an extend-
ed period may degrade the device and effect its reliability.
Electrical Characteristics
Parameter
Output Characteristics @ 25°C
Load Voltage (Peak)
Load Current (Continuous)
AC/DC Configuration
DC Configuration
Peak Load Current
On-Resistance
AC/DC Configuration
DC Configuration
Off-State Leakage Current
Switching Speeds
Turn-On
Turn-Off
Output Capacitance
Input Characteristics @ 25°C
Input Control Current
Input Dropout Current
Input Voltage Drop
Reverse Input Voltage
Reverse Input Current
Input to Output Capacitance
Input to Output Isolation
Conditions
Symbol Min Typ Max Units
-
-
-
10ms
IL=Load Current
IL=Load Current
VL=25OV
IF=5mA, VL=10V
IF =5mA, VL=10V
50V; f=1MHz
IL=Load Current
-
IF=5mA
-
VR=5V
-
-
VL
-
- 250
V
IL
-
- 150 mA
IL
-
- 200 mA
ILPK
-
-
-
mA
RON
- 15 20
Ω
-
5
6
Ω
ILEAK
-
-
1
µA
TON
-
-
3
ms
TOFF
-
-
3
ms
COUT
- 50 -
pF
IF
5
- 50
mA
IF
0.4 0.7 -
mA
VF
0.9 1.2 1.4
V
VR
-
-
5
V
IR
-
- 10
µA
CI/O
-
3
-
pF
VI/O
3750 -
-
VRMS
2
www.clare.com
Rev. 8