English
Language : 

LAA125L Datasheet, PDF (2/6 Pages) Clare, Inc. – Single Pole OptoMOS Relays
LAA125L
Absolute Maximum Ratings (@ 25˚ C)
Parameter
Blocking Voltage
Reverse Input Voltage
Input Control Current
Peak (10ms)
Input Power Dissipation 1
Total Power Dissipation 2
Isolation Voltage Input to Output
Operational Temperature
Storage Temperature
1 Derate Linearly 1.33 mw/˚C
2 Derate Linearly 6.67 mw/˚C
Ratings
350
5
50
1
150
800
3750
-40 to +85
-40 to +125
Units
VP
V
mA
A
mW
mW
Vrms
°C
°C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics
Parameter
Output Characteristics @ 25°C
Load Current
Peak Load Current
Load Current Limiting
On-Resistance
Off-State Leakage Current
Switching Speeds
Turn-On
Turn-Off
Output Capacitance
Input Characteristics @ 25°C
Input Control Current
Input Dropout Current
Input Voltage Drop
Reverse Input Current
Input to Output Capacitance
Conditions
Symbol
Min
Typ
Max Units
Continuous
IL
10ms max
ILPK
ICL
IL=Load Current
RON
VL=350V
ILEAK
IF=5mA, VL=10V
TON
IF=5mA, VL=10V
TOFF
50V; f=1MHz
COUT
IL=170mA
IF
-
-
IF=5mA
VF
VR=5V
IR
-
CI/O
-
-
150
mA
-
-
400
mA
190
235
280
mA
-
-
18
Ω
-
-
1
μA
-
-
5
ms
-
-
5
ms
-
50
-
pF
5
-
-
mA
0.4
0.7
-
mA
0.9
1.2
1.4
V
-
-
10
μA
-
3
-
pF
2
www.clare.com
Rev. 10