English
Language : 

LAA110L Datasheet, PDF (2/7 Pages) Clare, Inc. – Dual Pole OptoMOS Relays
LAA110L
Absolute Maximum Ratings (@ 25˚ C)
Parameter
Min Typ Max Units
Input Power Dissipation
-
- 1501 mW
Input Control Current
-
- 50 mA
Peak (10ms)
-
-
1A
Blocking Voltage DC or AC peak -
- 350 V
Reverse Input Voltage
-
-
5V
Total Power Dissipation
-
- 8002 mW
Isolation Voltage
Input to Output
Operational Temperature
3750 -
-
VRMS
-40 - +85 °C
Storage Temperature
-40 - +125 °C
Soldering Temperature
(10 Seconds Max.)
DIP Package
-
- +260 °C
Flatpack/Surface Mount
Package
-
- +220 °C
1 Derate Linearly 1.33 mw/˚C
2 Derate Linearly 6.67 mw/˚C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at these or
any other conditions beyond those indicated in the opera-
tional sections of this data sheet is not implied. Exposure
of the device to the absolute maximum ratings for an
extended period may degrade the device and effect its
reliability.
Electrical Characteristics
Parameter
Conditions
Symbol
Min
Output Characteristics @ 25°C
Load Current (Continuous)*
-
IL
-
Peak Load Current
10ms max
ILPK
-
On-Resistance
IL=120mA
RON
-
Off-State Leakage Current
VL=350V
ILEAK
-
Switching Speeds
Turn-On
IF=5mA, VL=10V
TON
-
Turn-Off
IF=5mA, VL=10V
TOFF
-
Output Capacitance
50V; f=1MHz
COUT
-
Load Current Limiting
-
ICL
130
Input Characteristics @ 25°C
Input Control Current
Input Dropout Current
IL=120mA
IF
5
-
-
0.4
Input Voltage Drop
IF=5mA
VF
0.9
Reverse Input Voltage
-
VR
-
Reverse Input Current
VR=5V
IR
-
Input to Output Capacitance
-
CI/O
-
*Note: If both poles operate load current must be derated so as not to exceed the package power dissipation valve.
Typ
Max
Units
-
120
mA
-
350
mA
30
35
Ω
-
1
µA
-
3
ms
-
3
ms
25
-
pF
170
210
mA
-
50
mA
0.7
-
mA
1.2
1.4
V
-
5
V
-
10
µA
3
-
pF
2
www.clare.com
Rev. 7.0