English
Language : 

LAA110 Datasheet, PDF (2/6 Pages) Clare, Inc. – Dual Pole OptoMOS Relays
LAA110
Absolute Maximum Ratings (@ 25˚ C)
Parameter
Input Power Dissipation
Input Control Current
Peak (10ms)
Reverse Input Voltage
Total Power Dissipation
Isolation Voltage
Input to Output
Operational Temperature
Storage Temperature
Soldering Temperature
(10 Seconds Max.)
DIP Package
Flatpack/Surface Mount
Package
1 Derate Linearly 1.33 mw/˚C
2 Derate Linearly 6.67 mw/˚C
Min Typ Max Units
-
- 1501 mW
-
- 50 mA
-
-1 A
-
-5 V
-
- 8002 mW
3750
-40
-40
-
- VRMS
- +85 °C
- +125 °C
-
- +260 °C
-
- +220 °C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at these or
any other conditions beyond those indicated in the opera-
tional sections of this data sheet is not implied. Exposure
of the device to the absolute maximum ratings for an
extended period may degrade the device and effect its
reliability.
Electrical Characteristics
Parameter
Conditions
Symbol Min
Typ
Output Characteristics @ 25°C
Load Voltage (Peak)
Load Current (Continuous)*
Peak Load Current
On-Resistance
Off-State Leakage Current
Switching Speeds
Turn-On
Turn-Off
Output Capacitance
Input Characteristics @ 25°C
-
VL
-
-
-
IL
-
-
10ms max
ILPK
-
-
IL=120mA
RON
-
25
VL=350V
ILEAK
-
-
IF=5mA, VL=10V
TON
-
-
IF=5mA, VL=10V
TOFF
-
-
50V; f=1MHz
COUT
-
25
Input Control Current
Input Dropout Current
IL=120mA
-
IF
5
-
-
0.4
0.7
Input Voltage Drop
IF=5mA
VF
0.9
1.2
Reverse Input Voltage
-
VR
-
-
Reverse Input Current
VR=5V
IR
-
-
Input to Output Capacitance
-
CI/O
-
3
Input to Output Isolation
-
VI/O
3750
-
*Note: If both poles operate load current must be derated so as not to exceed the package power dissipation valve.
Max
Units
350
V
120
mA
350
mA
35
Ω
1
µA
3
ms
3
ms
-
pF
50
mA
-
mA
1.4
V
5
V
10
µA
-
pF
-
VRMS
2
www.clare.com
Rev. 7