English
Language : 

LAA108 Datasheet, PDF (2/6 Pages) Clare, Inc. – Dual Single-Pole OptoMOS® Relay
LAA108
Absolute Maximum Ratings
Parameter
Ratings Units
Blocking Voltage
Reverse Input Voltage
100
VP
5
V
Input Control Current
50
mA
Peak (10ms)
1
A
Input Power Dissipation 1
150
mW
Total Power Dissipation 2
800
mW
Isolation Voltage Input to Output 3750
Vrms
Operational Temperature
-40 to +85 °C
Storage Temperature
-40 to +125 °C
1 Derate Linearly 1.33 mw/˚C
2 Derate Linearly 6.67 mw/˚C
Electrical absolute maximum ratings are at 25°C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics
Parameter
Output Characteristics @ 25°C
Conditions
Symbol
Min
Typ
Max
Load Current
Continuous 1
Peak
On-Resistance 2
Off-State Leakage Current
Switching Speeds
-
IL
t =10ms
ILPK
IL=300mA
RON
VL=100VP
ILEAK
-
-
300
-
-
400
-
4.5
8
-
-
1
Turn-On
Turn-Off
Output Capacitance
Input Characteristics @ 25°C
Input Control Current 3
Input Dropout Current
IF=5mA, VL=10V
tON
tOFF
50V, f=1MHz
COUT
IL=300mA
IF
-
-
-
0.43
3
-
0.17
3
-
110
-
-
0.5
2
0.2
0.3
-
Input Voltage Drop
Reverse Input Current
Common Characteristics @ 25°C
IF=5mA
VR=5V
VF
0.9
1.2
1.4
IR
-
-
10
Input to Output Capacitance
-
CI/O
-
3
-
1 If both poles operate simultaneously, the load current must be derated so as not to exceed the package total power dissipation value.
2 Measurement taken within one (1) second of on time.
3 For applications requiring high-temperature operation (T>60ºC), an LED drive currrent of 4mA is recommended.
Units
mA
Ω
μA
ms
pF
mA
mA
V
μA
pF
2