CPC1976 Datasheet, PDF (2/5 Pages) Clare, Inc. – AC Power Switch
CPC1976
Absolute Maximum Ratings (@ 25˚ C)
Parameter
Blocking Voltage (VDRM)
Reverse Input Voltage
Input Control Current
Peak (10ms)
Input Power Dissipation 1
Total Power Dissipation 2
Isolation voltage Input to Output
Operational Temperature
Storage Temperature
1 Derate Linearly 1.33 mW / ºC
2 Derate Linearly 20 mW / ºC
Ratings
600
5
50
1
150
2400
3750
-40 to +85
-40 to +125
Units
VP
V
mA
A
mW
mW
Vrms
°C
°C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristcs
Parameters
Output Characteristics @ 25°C
Load Current, Continuous
Maximum Surge Current
Off State Leakage Current
On-State Voltage Drop 1
Critical Rate of Rise
Switching Speeds
Turn-on
Turn-off
Zero-Cross Turn-On Voltage
Holding Current
Latching Current
Operating Frequency 2
Load Power Factor for
Guaranteed Turn-On 3
Input Characteristics @ 25°C
Input Control Current 4
Input Drop-out Voltage
Input Voltage Drop
Reverse Input Current
Common Characteristics @ 25°C
Input to Output Capacitance
Conditions
VL=120-240Vrms
t < 16ms
VDRM
IL=2Arms
-
IF = 5 mA
1st half cycle
Subsequent half cycle
-
-
-
60Hz
60Hz
-
IF=5mA
VR=5V
-
1 Tested at a peak value equivalent.
2 Zero Cross 1st half cycle @ <100Hz.
3 Snubber circuits may be required at low power factors.
4 For high-noise environments, or for high-frequency operation, use IF > 10mA.
Symbol Min Typ Max
IL
0.005 -
2
IPK
-
-
20
ILEAK
-
-
1
-
- 0.86 1.15
dv/dt 1000 1200 -
tON
-
- 0.5
tOFF
-
- 0.5
-
-
2
10
-
-
-
2
IH
- 0.82 5
IL
- 0.84 6
20 - 500
PF
0.25 -
-
IF
-
-
5
-
0.8 -
-
VF
0.9 1.2 1.4
IR
-
-
10
CI/O
-
-
3
Units
Arms
A
mA
Vrms
V/μs
cycles
cycles
V
V
mA
mA
Hz
-
mA
V
V
μA
pF
2
www.clare.com
R02