English
Language : 

CPC1945G_1 Datasheet, PDF (2/4 Pages) Clare, Inc. – AC Solid State Relay
CPC1945G
Absolute Maximum Ratings (@ 25˚ C)
Parameter
Ratings Units
Blocking Voltage
Reverse Input Voltage
400
VP
5
V
Input Control Current
Peak (10ms)
Input Power Dissipation1
PMAX , Total Package Dissipation 2
Isolation Voltage Input to Output
Operational Temperature
100
mA
1
A
150
mW
1600 mW
3750
Vrms
-40 to +85 °C
Storage Temperature
-40 to +125 °C
1 Derate Linearly 1.33 mW/ºC
2 Derate Linearly 16.6 mW/ºC
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristcs
Parameters
Conditions
Symbol
Min
Typ Max Units
Output Characteristics @ 25°C
Operating Voltage Range
Load Current, Continuous
Non-Repetitive Single Cycle Surge Current
Off State Leakage Current
On-State Voltage Drop
Critical Rate of Rise 3
VL
VL=120Vrms
-
VL=400VP
IL=1Arms
-
-
20
-
120
Vrms
IL
0.005
-
1.0
Arms
ITSM
-
-
10
A
ILEAK
-
-
1
mA
-
-
1.6
Vrms
dV/dt
1000
-
-
V/µs
Switching Speeds
Turn-on
Turn-off
Zero-Cross Turn-On Voltage
IF=5 mA
tON
-
-
0.5
cycles
tOFF
-
-
0.5
1st half cycle
-
-
2
10
V
Subsequent half cycle
-
-
1
-
V
Operating Frequency 1
-
-
20
-
400
Hz
Load Power Factor for Guaranteed Turn-On 2
-
PF
0.25
-
-
-
Input Characteristics @ 25°C
Input Control Current 4
Input Voltage Drop
Input Drop-out Voltage
-
IF=5mA
-
IF
-
0.8
5
mA
VF
0.9
1.2
1.4
V
-
0.8
-
-
V
Reverse Input Current
Common Characteristics @ 25°C
VR=5V
IR
-
-
10
µA
Input to Output Capacitance
-
1 Zero Cross 1st half cycle @ <100Hz
2 Snubber circuits may be required at low power factors.
3 Tested in accordance with EIA/NARM standard RS-443.
4 For high noise environments, use IF=10mA.
CI/O
-
3
-
pF
2
www.clare.com
R04