Absolute Maximum Ratings (@ 25˚ C)
Parameter
Ratings Units
Blocking Voltage
Reverse Input Voltage
400
VP
5
V
Input Control Current
Peak (10ms)
Input Power Dissipation1
PMAX , Total Package Dissipation 2
Isolation Voltage Input to Output
Operational Temperature
100
mA
1
A
150
mW
800
mW
3750
Vrms
-40 to +85 °C
Storage Temperature
-40 to +125 °C
1 Derate Linearly 1.33 mW/ºC
2 Derate Linearly 6.67 mW/ºC
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristcs
Parameters
Output Characteristics @ 25°C
Operating Voltage Range
Load Current, Continuous
Off State Leakage Current
On-State Voltage Drop
Critical Rate of Rise 3
Switching Speeds
Turn-on
Turn-off
Zero-Cross Turn-On Voltage
Conditions
Symbol Min
Typ Max Units
VL
-
20
-
120
Vrms
VL=120-240Vrms
IL
0.005
-
0.5
Arms
VL=400VP
ILEAK
-
-
1
mA
IL=500mArms
VON
-
-
1.4
Vrms
-
dV/dt
1000
-
-
V/µs
IF=5 mA
tON
-
-
0.5
cycles
tOFF
-
-
0.5
1st half cycle
-
-
2
10
V
Subsequent half cycle
-
Operating Frequency 1
-
Load Power Factor for Guaranteed Turn-On 2
-
PF
Input Characteristics @ 25°C
Input Control Current 4
Input Voltage Drop
Input Drop-out Voltage
-
IF
IF=5mA
VF
-
Reverse Input Current
VR=5V
IR
Common Characteristics @ 25°C
Input to Output Capacitance
-
CI/O
1 Zero Cross 1st half cycle @ <100Hz
2 Snubber circuits may be required at low power factors.
3 Tested in accordance with EIA/NARM standard RS-443.
4 For high noise environments, use IF=10mA.
-
1
-
V
20
-
500
Hz
0.25
-
-
-
-
0.8
5
mA
0.9
1.2
1.4
V
0.8
-
-
V
-
-
10
µA
-
3
-
pF
2
www.clare.com
R05