English
Language : 

CM15 Datasheet, PDF (2/4 Pages) Clare, Inc. – Molded DYAD
Molded DYAD®
CM15
Absolute Maximum Ratings (@ 25˚ C)
Parameter
Min Typ Max Units
Switching Voltage
CM15 - MOLDED DYAD®
Switching Current
CM15 - MOLDED DYAD®
Carry Current
CM15 - MOLDED DYAD®
Switching Frequency
CM15 - MOLDED DYAD®
Contact Resistance
CM15 - MOLDED DYAD®
(See detailed specifications for more information.)
200 Volts
0.5 Amps
1.5 Amps
500 Hz
150 mΩ
Absolute Maximum Ratings are stress ratings. Stresses
in excess of these ratings can cause permanent damage
to the device. Functional operation of the device at these
or any other conditions beyond those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to the absolute maximum ratings
for extended period may degrade the device and effect
its reliability.
Specifications
All parameters are at 25°C unless otherwise stated.
PARAMETER
CONDITIONS
SYMBOL MIN
Contact Ratings
Operate ampere turns range
Full Blade Tolerance = ± 1.5NI
AT
10
Release ampere turns range
Full Blade Tolerance = ± 1.5NI
AT
5
Switching Voltage
Switching Current
Carry Current
Contact Rating
Max DC/PeakAC Resistive
V
-
L
Max DC/PeakAC Resistive
IL
-
Max DC/PeakAC Resistive
IC
-
Max DC/PeakAC Resistive
-
-
Life Expectancy
1V, 10mA Signal Level
-
-
10V, 10mA Low Level
-
-
50V, 100mA Telecom Load
-
-
100V, 100mA Rated Loads
-
-
Static Contact Resistance
50mV, 10mA(1)
CR
-
Contact Material
-
-
Switch Specifications
Insulation Resistance(2)
100V, 25°C, 40% RH
IR
109
Capacitance
Across Open Contacts
-
-
Dielectric Strength(5)
Between Contacts
-
250
Operate Time,
including bounce
At nominal coil voltage,
T
-
OP
10Hz Square Wave
Release Time
Environmental Ratings
Zener-Diode Suppression(3)
T
-
REL
Storage Temperature
Operating Temperature
Soldering Temperature
T
-40
A
T
-40
O
-
-
Vibration
5Hz - 200Hz
G
-
Shock
Shock - survivability
11±1ms, 1/2 Sine Wave
S
-
11±1ms, 1/2 Sine Wave
S
-
(1) Contact resistance measured with 4 terminal method, 1.1" between test leads
(2) >1012 Ω is available upon request
(3) A 24V zener in series with a diode across the coil
(4) Use caution not to exceed vibration resistance limits while ultrasonically cleaning. Contact Clare Engineering for more details/recommendations
(5) 15 ampere turn minimum
TYP
-
-
-
-
-
-
1000
500
2
2
80
Ru
1011
0.3
300
-
-
-
-
-
-
-
-
MAX
UNITS
30
NI
30
NI
200
VDC
500
mAmps
1.5
Amps
10
VA
-
x106 Ops
-
x106 Ops
-
x106Ops
-
x106 Ops
150
mΩ
-
-
-
Ω
-
pF
- VDC/Peak AC
0.5
ms
0.2
ms
+125
°C
+125
°C
+240
°C
20
-Gs
30
Gs
500
Gs
2
www.clare.com
Rev. 1