CPC5620/CPC5621
4. Regulatory Information
LITELINK can be used to build products that comply
The information provided in this document is intended
with the requirements of TIA/EIA/IS-968 (formerly
to inform the equipment designer but it is not sufficient
FCC part 68), FCC part 15B, TBR-21, EN60950,
to assure proper system design or regulatory compli-
UL1950, EN55022B, IEC950/IEC60950, CISPR22B,
ance. Since it is the equipment manufacturer's
EN55024, and many other standards. LITELINK com-
responsibility to have their equipment properly
plies with the requirements of UL1577. LITELINK pro-
designed to conform to all relevant regulations,
vides supplementary isolation. Metallic surge
designers using LITELINK are advised to carefully
requirements are met through the inclusion of a Sidac-
verify that their end-product design complies with all
tor in the application circuit. Longitudinal surge protec-
tion is provided by LITELINK’s optical-across-the-
barrier technology and the use of high-voltage compo-
nents in the application circuit as needed.
5. LITELINK Design Resources
applicable safety, EMC, and other relevant standards
and regulations. Semiconductor components are not
rated to withstand electrical overstress or electro-static
discharges resulting from inadequate protection mea-
inary sures at the board or system level.
5.1 Clare, Inc. Design Resources
The Clare, Inc. web site has a wealth of information
lim useful for designing with LITELINK, including applica-
tion notes and reference designs that already meet all
applicable regulatory requirements. LITELINK data
sheets also contains additional application and design
e information. See the following links:
r LITELINK datasheets and reference designs
P Application note AN-107 LOCxx Series - Isolated Ampli-
Application note AN-149, Increased LITELINK II Transmit
Power
Application note AN-150, Ground-start Supervision Cir-
cuit Using IAA110.
5.2 Third Party Design Resources
The following also contain information useful for DAA
designs. All of the books are available on ama-
fier Design Principles
zon.com.
Application note AN-114 ITC117P
Application note AN-117 Customize Caller-ID Gain and
Ring Detect Voltage Threshold for CPC5610/11
Application note AN-140, Understanding LITELINK
Understanding Telephone Electronics, Stephen J. Big-
elow, et. al., Butterworth-Heinemann; ISBN:
0750671750
Newton’s Telecom Dictionary, Harry Newton, CMP
Books; ISBN: 1578200695
Application note AN-141, Enhanced Pulse Dialing with
LITELINK
Application note AN-143, Loop Reversal Detection with
LITELINK
Photodiode Amplifiers: Op Amp Solutions, Jerald
Graeme, McGraw-Hill Professional Publishing; ISBN:
007024247X
Teccor, Inc. Surge Protection Products
Application note AN-146, Guidelines for Effective
LITELINK Designs
United States Code of Federal Regulations, CFR 47
Part 68.3
Application note AN-147, Worldwide Application of
LITELINK
14
www.clare.com
Rev. 0.E