CLR132W Datasheet, PDF (1/1 Pages) Clairex Technologies, Inc – NPN Silicon Photodarlingtons
CLR130W,CLR131W,CLR132W
NPN Silicon Photodarlingtons CLR130W, CLR131W, and CLRW132 are
exact replacements for obsolete part numbers
CLR2049, CLR2050 and CLR2060.
0.190 (4.83)
0.176 (4.47)
0.210 (5.33)
0.190 (4.83)
0.500 (12.7) min
® Clairex
Technologies, Inc.
April, 2002
0.215 (5.46)
0.205 (5.21)
0.160 (4.06)
0.150 (3.81)
0.010 (0.25)
max
0.025 (0.64)
max
COLLECTOR
BASE
EMITTER
0.100 (2.54) dia
0.019 (0.48)
0.016 (0.41)
0.147 (3.73)
0.137 (3.48)
ALL DIMENSIONS ARE IN INCHECSa(sMeIL1L8IMETERS)
features
• high sensitivity
• ±35° acceptance angle
• TO-18 hermetically sealed package
• transistor base is bonded
• RoHS compliant
description
The CLR130W-CLR132W series are
NPN silicon photodarlingtons
mounted in TO-18 flat window
packages. The wide acceptance
angle provided by the flat window
enables even reception over a
relatively large area.
Photodarlingtons allow high
sensitivity at low irradiance levels
These devices are mechanically
and spectrally matched to the
CLE130-CLE133 series IREDs. For
additional information, call Clairex.
absolute maximum ratings (TA = 25°C unless otherwise stated)
storage temperature........................................................................-65°C to +150°C
operating temperature ....................................................................-65°C to +125°C
lead soldering temperature(1)..........................................................................260°C
collector-emitter voltage .................................................................................... 15V
continuous collector current ........................................................................... 50mA
continuous power dissipation(2) ....................................................................250mW
notes:
1. 0.06” (1.5mm) from the header for 5 seconds maximum
2. Derate linearly 2.0mW/°C from 25°C free air temperature to TA = +125°C.
electrical characteristics (TA = 25°C unless otherwise noted)
symbol
parameter
min typ
max units test conditions
Light current(1)
IL
CLR130W
CLR131W
CLR132W
0.2
-
0.6
-
1.4
-
-
-
mA
mA
VCE=5V, Ee=0.06mW/cm2
-
mA
ICEO
Collector dark current
-
-
100
nA
VCE=10V, Ee=0
V(BR)CEO
Collector-emitter breakdown
15
-
-
V
IC=100µA
tr
Output rise time
-
100
-
µs
VCE=5V, RL=100Ω.
tf
Output fall time
-
150
-
µs
VCE=5V, RL=100Ω.
θHP
Total angle at half sensitivity points
-
70
-
deg.
note: 1. Radiation source for all light current testing is a 940nm IRED.
Clairex reserves the right to make changes at any time to improve design and to provide the best possible product.
Revised 3/13/06
Clairex Technologies, Inc.
Phone: 972-265-4900
1301 East Plano Parkway
Fax: 972-265-4949
Plano, Texas 75074-8524