DATA SHEET
6/11
6. Reliability
(1)Datails of the tests
Test Item
Test Condition
Continuous Operation Test
IF=720mA Ta=25C (with Al-fin) × 1000 hours
IF=720mA Tj=140C (with Al-fin) × 1000 hours
Low Temperature Storage Test -40 C × 1000 hours
High Temperature Storage Test 100 C × 1000 hours
Moisture-proof Test
85 C, 85 %RH for 500 hours
Thermal Shock Test
-40 C × 30 minutes – 100 C × 30 minutes, 100 cycle
(2)Judgement Criteria of Failure for Reliability Test
Measuring Item
Forward Voltage
Total Luminous Flux
Symbol
VF
Φv
Measuring Condition
IF=720mA
IF=720mA
(Ta=25C)
Judgement Criteria for Failure
>U X 1.1
<S X 0.85
U defines the upper limit of the specified characteristics. S defines the initial value.
Note : Measurement shall be taken between 2 hours and 24 hours, and the test pieces should be
return to the normal ambient conditions after the completion of each test.
Symbol
CITILED
Name
CLL032-1212A5-273H3D2
CITIZEN ELECTRONICS CO.,LTD. JAPAN
Ref.CE-P2580 11/13