Features
•
Low power consumption .12W
•
Ultra light weight
•
Narrow width for high density mounting
•
UL/CUL certified
J112
20.2 x 5.3 x 12.8 mm
Contact Data
Contact Arrangement
Contact Rating
1A = SPST N.O.
5A @ 250VAC Resistive
5A @ 30VDC Resistive
Contact Resistance
Contact Material
Maximum Switching Power
Maximum Switching Voltage
Maximum Switching Current
< 50 milliohms initial
AgSnO2
150W, 1250VA
250VAC, 110VDC
5A
Coil Data
Coil Voltage
VDC
Rated Max
5
6.5
6
7.8
9
11.7
12
15.6
18
23.4
24
31.2
Coil Resistance
Ω +/- 10%
Pick Up Voltage Release Voltage
VDC (max)
VDC (min)
75% of rated
voltage
10% of rated
voltage
208
3.75
.5
300
4.50
.6
675
6.75
.9
1200
9.00
1.2
2700
13.50
1.8
3200
18.00
2.4
Coil Power
W
.12
.18
Operate Time
ms
Release Time
ms
10
5
General Data
Electrical Life @ rated load
Mechanical Life
Insulation Resistance
Dielectric Strength, Coil to Contact
Contact to Contact
Shock Resistance
Vibration Resistance
Terminal (Copper Alloy) Strength
Operating Temperature
Storage Temperature
Solderability
Weight
100K cycles, typical
10M cycles, typical
100M Ω min. @ 500VDC
2000V rms min. @ sea level
1000V rms min. @ sea level
100m/s2 for 11 ms
1.50mm double amplitude 10~40Hz
5N
-40oC to +85oC
-40oC to +155oC
260oC for 5 s
3g
Caution
1. The use of any coil voltage less than the
rated coil voltage may compromise the
operation of the relay.
www.citrelay.com