English
Language : 

J1051A3VDC Datasheet, PDF (1/2 Pages) CIT Relay & Switch – CIT SWITCH
J105
FEATURES:
• Switching capacity up to 10A
• Small size and light weight
• Low coil power consumption
• High contact load
E197852
RoHS Compliant
18.5 x 10.2 x 15.8 mm
CONTACT DATA
Contact Arrangement
Contact Rating
Contact Resistance
Contact Material
Maximum Switching Power
Maximum Switching Voltage
Maximum Switching Current
1A = SPST N.O
1C = SPDT
4.2A @ 277VAC; 5A @ 250VAC
10A @ 125VAC Resistive
¼ hp, 120/250/277VAC
TV-5, 120VAC; Pilot Duty: C150
< 50 milliohms initial
AgSnO2
150W 1250VA
277VAC, 30VDC
10A
COIL DATA
Coil Voltage
VDC
Coil Resistance
Ω ± 10%
Pick Up Voltage
VDC (max)
Release Voltage
VDC (min)
Coil Power
W
Operate Time
ms
Release Time
ms
75%
10%
Rated Max.
.45W
of rated voltage of rated voltage
3
3.9
20
2.25
0.3
5
6.5
55
3.75
0.5
6
7.8
80
4.50
0.6
9 11.7
180
6.75
0.9
.45
10
10
12 15.6
320
9.00
1.2
18 22.8
720
13.50
1.8
24 31.2
1280
18.00
2.4
48 62.4
5120
36.00
4.8
CAUTION:
1. The use of any coil voltage less than the rated coil voltage may compromise the operation of the relay.
2. Pickup and release voltages are for test purposes only and are not to be used as design criteria.
GENERAL DATA
Electrical Life @ rated load
Mechanical Life
Insulation Resistance
Dielectric Strength, Coil to Contact
Contact to Contact
Shock Resistance
Vibration Resistance
Terminal (Copper Alloy) Strength
Operating Temperature
Storage Temperature
Solderability
Weight
100K cycles, typical
10M cycles, typical
100MΩ min @ 500VDC
4000V rms min. @ sea level
1000V rms min. @ sea level
100m/s2 for 11ms
1.50mm double amplitude 10-40Hz
10N
-40°C to + 85°C
-40°C to + 155°C
260 °C for 5s
9.5g
www.citrelay.com
phone – 763.535.2339 fax – 763.535.2194