English
Language : 

J0991AS3VDC.45 Datasheet, PDF (1/2 Pages) CIT Relay & Switch – CIT SWITCH
RoHS Compliant
E197851
Features
•
High sensitivity
•
Super light weight
•
Switching current up to 12A
•
PC board mounting
Contact Data
Contact Arrangement
Contact Rating
1A = SPST N.O.
10A @ 277VAC
10A @ 30VDC
12A @ 125VAC
J099
18.4 x 15.0 x 10.3 mm
Contact Resistance
Contact Material
Maximum Switching Power
Maximum Switching Voltage
Maximum Switching Current
< 50 milliohms initial
AgSnO2
300W
300VAC, 100VDC
12A
Coil Data
Coil Voltage
VDC
Rated
Max
3
3.9
5
6.5
6
7.8
9
11.7
12
15.6
18
23.4
24
31.2
Coil
Resistance
Ω +/- 10%
20
56
80
180
320
720
1280
Pick Up
Voltage VDC
(max)
Release Volt-
age
VDC (min)
75% of rated
voltage
2.25
3.75
4.50
6.75
9.00
13.50
18.00
10% of rated
voltage
.3
.5
.6
.9
1.2
1.8
2.4
Coil Power
W
.45
Operate Time
ms
Release Time
ms
8
5
General Data
Electrical Life @ rated load
Mechanical Life
Insulation Resistance
Dielectric Strength, Coil to Contact
Contact to Contact
Shock Resistance
Vibration Resistance
Terminal (Copper Alloy) Strength
Operating Temperature
Storage Temperature
Solderability
Weight
100K cycles, typical
10M cycles, typical
100M Ω min. @ 500VDC
2500V rms min. @ sea level
1000V rms min. @ sea level
100m/s2 for 11 ms
1.50mm double amplitude 10~40Hz
5N
-40oC to +85oC
-40oC to +155oC
260oC for 5 s
7g
Caution
1. The use of any coil voltage less than the
rated coil voltage may compromise the
operation of the relay.
www.citrelay.com
phone - 763.535.2339 fax - 763.535.2194