Features
•
H-Bridge contact configuration available
•
Small size and light weight
•
25A switching capacity
•
F Class materials standard
•
QS-9000, ISO-9002 Certified Manufacturing
Contact Data
Contact Arrangement
Contact Rating
1C = SPDT
1H = H Bridge
25A @ 14VDC
A16
14.5 x 14.0x 14.3 mm 14.5 x 7.7 x 13.7 mm
Contact Resistance
Contact Material
Maximum Switching Power
Maximum Switching Voltage
Maximum Switching Current
< 50 milliohms initial
AgSnO2In2O3
480W
20VDC
30A
Coil Data
Coil Voltage
VDC
Rated Max
12
15.6
Coil Resistance
Ω +/- 10%
.64W
225
.80W
180
Pick Up Voltage Release Voltage
VDC (max)
VDC (min)
70% of rated
voltage
8.40
10% of rated
voltage
1.2
Coil Power
W
.64 & .80
Operate Time
ms
Release Time
ms
10
5
General Data
Electrical Life @ rated load
Mechanical Life
Insulation Resistance
Dielectric Strength, Coil to Contact
Contact to Contact
Shock Resistance
Vibration Resistance
Terminal (Copper Alloy) Strength
Operating Temperature
Storage Temperature
Solderability
Weight
100K cycles, typical
10M cycles, typical
100M Ω min. @ 500VDC
1500V rms min. @ sea level
1000V rms min. @ sea level
100m/s2 for 11 ms
1.27mm double amplitude 10~40Hz
4N
-40oC to +105oC
-40oC to +155oC
260oC for 5 s
4.1g
Caution
1. The use of any coil voltage less than the
rated coil voltage may compromise the
operation of the relay.
www.citrelay.com