English
Language : 

A141ACQ12VDC Datasheet, PDF (1/2 Pages) CIT Relay & Switch – CIT SWITCH
RoHS Compliant
Features
•
Large switching capacity up to 100A
•
Ideal for high inrush applications
•
Quick connect mounting available
•
Suitable for automobile and lamp accessories
•
QS-9000, ISO-9002 Certified Manufacturing
A14
32.6 x 34.6 x 34.0 mm
Contact Data
Contact Arrangement
Contact Rating
1A = SPST N.O.
1C = SPDT
1A : 100A @ 12VDC
1A : 50A @ 24VDC
1C : N.O. 100A @ 12VDC
1C : N.O. 50A @ 24VDC
1C : N.C. 70A @ 12VDC
1C : N.C. 35A @ 24VDC
Contact Resistance
Contact Material
Maximum Switching Power
Maximum Switching Voltage
Maximum Switching Current
< 30 milliohms initial
AgSnO2In2O3
1200W
75VDC
100A
Coil Data
Coil Voltage
VDC
Rated Max
12
15.6
24
31.2
Coil Resistance
Ω +/- 10%
50
155
Pick Up Voltage Release Voltage
VDC (max)
VDC (min)
70% of rated
voltage
8.40
16.80
10% of rated
voltage
1.2
2.4
Coil Power
W
2.90
Operate Time
ms
Release Time
ms
10
5
General Data
Electrical Life @ rated load
Mechanical Life
Insulation Resistance
Dielectric Strength, Coil to Contact
Contact to Contact
Shock Resistance
Vibration Resistance
Terminal (Copper Alloy) Strength
Operating Temperature
Storage Temperature
Solderability
Weight
100K cycles, typical
10M cycles, typical
100M Ω min. @ 500VDC
2500V rms min. @ sea level
1500V rms min. @ sea level
147m/s2 for 11 ms
1.50mm double amplitude 10~40Hz
30N
-40oC to +85oC
-40oC to +155oC
260oC for 5 s
60g
Caution
1. The use of any coil voltage less than the
rated coil voltage may compromise the
operation of the relay.
2. For Dry Circuit application contact factory
3. The coil has a 1K ohm resistor in parallel
that is taken into account in the coil
resistance specification
page 97
www.citrelay.com
phone - 763.535.2339 fax - 763.535.2194