SA305 Datasheet, PDF (8/8 Pages) Cirrus Logic – PULSE WIDTH MODULATION AMPLIFIER
SA305
OPERATING
CONSIDERATIONS
The warning temperature setting is fixed at TJ = 135°C.
When the junction temperature gets to the programmed point,
the temperature warning bit will be set. It will be reset when
the temperature falls below 85°C.
The Fault temperature setting is fixed at TJ = 160°C. Once
the Fault temperature has been reached the Fault Output goes
high and the outputs of the device are latched off. This output
can be used as a microcontroller interrupt. The latch will not
be reset until the temperature is below 110°C.
If more than one output is required to be conducting large
currents at the same time, the maximum current will need to
be de-rated.
CURRENT SENSE LINEARITY CALCULATION
The current sense linearity is calculated using the method
described below:
a) Define straight line (y = mx + c) joining the two end data
points where, m is the slope and c is the offset or zero
crossover. Calculate the slope m and offset c using the
extreme data points. Assume Isense in the y axis and Iload
in the x axis.
b) Calculate linear Isense (or ideal Isense value, ISIDEAL) using
the straight line equation derived in step (a) for the Iload
data points.
c) Determine deviation from linear Isense (step (b)) and actual
measured Isense value (ISACTUAL) as shown below:
%FWJBUJPOGSPN-JOFBSJUZ
*4*%&"-m*4"$56"-
*4*%&"-
r