English
Language : 

CS4365_07 Datasheet, PDF (17/52 Pages) Cirrus Logic – 114 dB, 192 kHz 6-Channel D/A Converter
CS4365
SWITCHING CHARACTERISTICS - CONTROL PORT - I²C FORMAT
Inputs: Logic 0 = GND, Logic 1 = VLC, CL = 20 pF.
Parameter
Symbol
Min
Max
SCL Clock Frequency
fscl
-
RST Rising Edge to Start
tirs
500
Bus Free Time Between Transmissions
tbuf
4.7
Start Condition Hold Time (prior to first clock pulse)
thdst
4.0
Clock Low time
tlow
4.7
Clock High Time
thigh
4.0
Setup Time for Repeated Start Condition
tsust
4.7
SDA Hold Time from SCL Falling
(Note 17)
thdd
0
SDA Setup time to SCL Rising
tsud
250
Rise Time of SCL and SDA
trc, trc
-
Fall Time SCL and SDA
tfc, tfc
-
Setup Time for Stop Condition
tsusp
4.7
Acknowledge Delay from SCL Falling
tack
300
100
-
-
-
-
-
-
-
-
1
300
-
1000
Unit
kHz
ns
µs
µs
µs
µs
µs
µs
ns
µs
ns
µs
ns
Notes:
17. Data must be held for sufficient time to bridge the transition time, tfc, of SCL.
RST
t irs
Stop
Start
Repeated
Start
SDA
SCL
t buf
t hdst
t high
t hdst
tf
t low t hdd
t sud
t sust
tr
Figure 4. Control Port Timing - I²C Format
Stop
t susp
DS670F1
17