VRE100_10 Datasheet, PDF (1/5 Pages) Cirrus Logic – Precision Voltage Reference | |||
|
VRE100P r,oVd uRc Et I1n0n 1o v,aVt iRo nEF1r 0o m2
VRE100/10V1R/1E10020
Precision Voltage Reference
FEATURES
⦠Very High Accuracy: ±10 V Output, ±1.0 mV
⦠Extremely Low Drift: 1.0 ppm/ºC (-55ºC to
+125ºC)
⦠Low Warm-up Drift: 1.0 ppm Typical
⦠Excellent Stability: 6 ppm/1000 Hrs. Typical
⦠Excellent Line Regulation: 3 ppm/V Typical
⦠Hermetic 14-pin Ceramic DIP
⦠Military Processing Option
APPLICATIONS
⦠Precision A/D and D/A Converters
⦠Transducer Excitation
⦠Accurate Comparator Threshold Reference
⦠High Resolution Servo Systems
⦠Digital Voltmeters
⦠High Precision Test and Measurement Instru-
ments
DESCRIPTION
VRE100 Series Precision Voltage References provide
ultrastable +10 V (VRE100), -10 V (VRE101) and ±10
V (VRE102) outputs with ±1.0 mV initial accuracy and
temperature coefficient as low as 1.0 ppm/°C over the
full military temperature range. This improvement in
accuracy is made possible by a unique, proprietary
multipoint laser compensation technique.
Significant improvements have been made in other
performance parameters as well, including initial ac-
curacy, warm-up drift, line regulation, and long-term
stability, making the VRE100 series the most accurate
and stable 10 V reference available.
VRE100/101/102 devices are available in two oper-
ating temperature ranges, -25°C to +85°C and -55°C
to +125°C, and two performance grades. All devices
are packaged in 14-pin hermetic ceramic packages
for maximum long-term stability. âMâ versions are
screened for high reliability and quality.
Superior stability, accuracy, and quality make these
references ideal for precision applications such as A/D
and D/A converters, high-accuracy test and measure-
ment instrumentation, and transducer excitation.
Figure 1. BLOCK DIAGRAMS
VRE100
VRE102
VRE100DS
www.cirrus.com
Copyright © Cirrus Logic, Inc. 2009
(All Rights Reserved)
NOV 20091
APEX â VRE100DSREVG
|
▷ |