English
Language : 

GBU6A Datasheet, PDF (1/1 Pages) Pan Jit International Inc. – GLASS PASSIVATED SINGLE-PHASE BRIDGE RECTIFIER(VOLTAGE - 100 Volts CURRENT - 6.0 Amperes)
CHONGQING PINGYANG ELECTRONICS CO.,LTD.
GBU6A THRU GBU6K
GLASS PASSIVATED BRIDGE RECTIFIER
VOLTAGE:50-800V
CURRENT:6.0A
FEATURES
·Low leakage
·Low forward voltage
·Surge overload ratings-175 Amperes
GBU
MECHANICAL DATA
·Case: Molded plastic
·Epoxy: UL 94V-0 rate flame retardant
·Lead: MIL-STD- 202E, Method 208 guaranteed
·Polarity: Symbols molded or marked on body
·Mounting position: Any
·Weight: 6.6 grams
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRONICAL CHARACTERISTICS
Ratings at 25℃ ambient temperature unless otherwise specified.
Single phase, half wave, 60Hz,resistive or inductive load.
For capacitive load, derate current by 20%.
SYMBOL GBU6A GBU6B GBU6D GBU6G GBU6J GBU6K units
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
V
Maximum RMS Bridge Input Voltage
VRMS 35 70 140 280 420 560 V
Maximum DC Blocking Voltage
VDC
50
100
200
400
600
800
V
Maximum Average Forward rectified Output
Current at TC=75°C
Io
6.0
A
Peak Forward Surge Current 8.3ms single half
sine-wave superimposed on rate load (JEDEC IFSM
method)
175
A
Maximum Forward Voltage Drop per element at
3.0 A DC
VF
1.0
V
Maximum DC Reverse Current
@ TA=25°C
at Rated DC Blocking Voltage
IR
per element
@ TA=125°C
I2t Rating for Fusing (t<8.3ms)
I2t
Typical Junction Capacitance per Element(Note 1) CJ
Typical Thermal Resistance, Junction to Case
(Note 2)
RθJA
5.0
µA
500
240
A2S
60
pF
2.7
°C/W
Notes: 1. Measured at 1.0 MHz and applied reverse voltage of 4.0V DC.
2. Thermal resistance from junction to case per element. Unit mounted on 150 x 150 x 1.6mm copper plate heat sink.