English
Language : 

SFR101PT Datasheet, PDF (1/2 Pages) Chenmko Enterprise Co. Ltd. – FAST SWITCHING RECTIFIER
CHENMKO ENTERPRISE CO.,LTD
SOFT RECOVERY
FAST SWITCHING RECTIFIER
VOLTAGE RANGE 50 - 800 Volts CURRENT 1.0 Ampere
SFR101PT
THRU
SFR106PT
FEATURES
* Plastic package has Underwriters Laboratory
Flammability Classification 94V-0
* High reliability
* Low leakage
* Low forward voltage drop
* High current capability
* High surge capability
* Fast switching
DO-41
MECHANICAL DATA
Case: JEDEC DO-41 molded plastic
Terminals: Plated axial leads, solderable per MIL-STD-750,
Method 2026
Polarity: Color band denotes cathode end
Mounting Position: Any
Weight: 0.33 gram
1.0(25.4)
MIN.
0.034(0.9)
0.028(0.7) DIA.
0.205(5.2)
0.166(4.2)
1.0(25.4)
MIN.
0.107(2.7)
0.080(2.0) DIA.
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25oC ambient temperature unless otherwise specified.
Single phase, half wave, 60 HZ, resistive or inductive load.
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
DO-41
MAXIMUM RATINGES ( At TA = 25oC unless otherwise noted )
RATINGS
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Current at TA = 55oC
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Junction Capacitance (Note 1)
Operating Temperature Range
Storage Temperature Range
SYMBOL
VRRM
VRMS
VDC
IO
SFR101PT SFR102PT SFR103PT SFR104PT SFR105PT SFR106PT UNITS
50
100
200
400
600
800 Volts
35
70
140
280
420
560 Volts
50
100
200
400
600
800 Volts
1.0
Amps
IFSM
30
Amps
CJ
TJ
TSTG
12
pF
-65 to +125
oC
-65 to +150
oC
ELECTRICAL CHARACTERISTICS ( At TA = 25oC unless otherwise noted )
CHARACTERISTICS
SYMBOL
Maximum Instantaneous Forward Voltage at 1.0 A DC
VF
Maximum DC Reverse Current
at Rated DC Blocking Voltage at TA = 25oC
IR
Maximum Full Load Reverse Current Average,
Full Cycle 0.375" (9.5mm) lead length at TL = 55oC
Maximum Reverse Recovery Time (Note 2)
trr
NOTES : 1. Measured at 1.0 MHZ and applied reverse voltage of 4.0 volts
2. Test Conditions : IF = 0.5 A, IR = -1.0 A, IRR = -0.25 A
SFR101PT SFR102PT SFR103PT SFR104PT SFR105PT SFR106PT UNITS
1.3
Volts
10
uAmps
100
100
uAmps
200
nSec
2001-6