English
Language : 

RABS152 Datasheet, PDF (1/2 Pages) DIYI Electronic Technology Co., Ltd. – High surge current capability
RABS152 THRU RABS1510
GLASS PASSIVATED FAST RECOVERY BRIDGE RECTIFIERS
Voltage Range - 200 to 1000 Volts Current - 1.5 Ampere
ABS
FEATURES
Ideal for printed circuit board
Reliable low cost construction utilizing
molded plastic technique
High temperature soldering guaranteed:
260 /10 seconds at 5 lbs., (2.3kg) tension
Small size, simple installation
Leads solderable per MIL-STD-202,
Method 208
High surge current capability
Glass passivated chip junction
Green compound(halogen&Sb2O3 free)
MECHANICAL DATA
Dimensions in inches and (millimeters)
Case: Molded plastic body
Terminals: Plated leads solderable per MIL-STD-750,
Method 2026
Polarity: Polarity symbols marked on case
Mounting Position: Any
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 ambient temperature unless otherwise specified.
Single phase half-wave 60Hz,resistive or inductive load, for capacitive load derate current by 20%.
MDD Catalog Number
MDD Mark
Maximum repetitive peak reverse voltage
Maximum RMS voltage
Maximum DC blocking voltage
SYMBOLS RABS152 RABS154 RABS156
F15T02 F15T04 F15T06
VRRM
200
400
600
VRMS
140
280
420
VDC
200
400
600
RABS158 RABS1510 UNITS
F15T08 F15T10
800
1000
V
560
700
V
800
1000
V
Maximum average forward rectified current
at Tc=125°C
IF(AV)
1.5
A
Peak forward surge current,
8.3ms single half sine-wave superimposed on
IFSM
50
A
rated load
Maximum instantaneous forward voltage drop
VF
per leg at 1.5A
1.3
V
Maximum DC reverse current TA=25
at rated DC blocking voltage TA=125
IR
5.0
100
uA
R JL
65
Typical thermal resistance(NOTE 3)
R JA
16
/W
Typical Junction Capacitance
Cj
30
pF
Maximum reverse recovery time (NOTE 4)
trr
200
ns
Operating temperature range
TJ, TSTG
-55 to +150
NOTES:1.On glass epoxy P.C.B. mounted on 0.05x0.05''(1.3x1.3mm) pads.
2.On aluminum substrate P.C.B. with an area of 0.8''x0.8''(20x20mm) mounted on 0.05X0.05''(1.3X1.3mm) solder pad.
3.Thermal resistance form junction to ambient and junction to lead mounted on P.C.B. with 0.2X0.2''(5X5mm) copper pads.