EMZR6R3ADA681MF80G Datasheet, PDF (1/2 Pages) United Chemi-Con, Inc. – SURFACE MOUNT ALUMINUM ELECTROLYTIC CAPACITORS | |||
|
SURFACE MOUNT ALUMINUM ELECTROLYTIC CAPACITORS
Low ESR, 105â
MZR AIchipTM-
Series
ã»Downsizing and Lower ESR, 2,000hours at 105â
ã»Rated voltage range : 6.3 to 50V, Nominal capacitance range : 100 to 2,200μF
ã»Solvent resistant type(see PRECAUTIONS AND GUIDELINES)
ã»Vibration resistance structure
ã»RoHS Compliant
ã»AEC-Q200 compliant : Please contact Chemi-Con for more details, test data, information.
MZR
Downsized
MZJ P98
âSPECIFICATIONS
Items
Category
Temperature Range
Rated Voltage Range
Capacitance Tolerance
Leakage Current
Dissipation Factor
(tanÐ)
Low Temperature
Characteristics
(Max. Impedance Ratio)
Endurance
Shelf Life
Surge Voltage Test
Characteristics
-55 to +105â
6.3 to 50Vdc
±20% (M)
(at 20â, 120Hz)
I=0.01CV or 3μA, whichever is greater.
Where, I : Max. leakage current (μA), C : Nominal capacitance (μF), V : Rated voltage (V)
(at 20â after 2 minutes)
Rated voltage (Vdc)
6.3V 10V 16V 25V 35V 50V
(at 20â, 120Hz)
tanδ(Max.)
0.26 0.19 0.16 0.14 0.12 0.10
Rated voltage (Vdc)
6.3V 10V 16V 25V 35V 50V
(at 120Hz)
Z(-25â)/Z(+20â)
222222
Z(-40â)/Z(+20â)
333333
Z(-55â)/Z(+20â)
444333
The following speciï¬cations shall be satisï¬ed when the capacitors are restored to 20â after the rated voltage is applied for 2,000 hours
at 105â.
Capacitance change
â¦Â±30% of the initial value
D.F. (tanδ)
â¦200% of the initial speciï¬ed value
Leakage current
â¦The initial speciï¬ed value
The following speciï¬cations shall be satisï¬ed when the capacitors are restored to 20â after exposing them for 1,000 hours at 105â without
voltage applied. Before the measurement, the capacitor shall be preconditioned by applying voltage according to Item 4.1 of JIS C 5101-4.
Capacitance change
â¦Â±30% of the initial value
D.F. (tanδ)
â¦200% of the initial speciï¬ed value
Leakage current
â¦The initial speciï¬ed value
The capacitors shall be subjected to 1,000 cycles each consisting of charging with the speciï¬ed surge voltage for 30±5 seconds through
a protective resistor (as required for RC=0.1±0.05sec) and open-circuiting for 5.5 minutes at a room temperature of 15 to 35â.
Rated voltage (Vdc)
6.3V 10V 16V 25V 35V 50V
Surge voltage (Vdc)
7.2V 12V 18V 29V 40V 58V
Appearance
No signiï¬cant damage
Capacitance change
â¦Â±20% of the initial value
D.F. (tanδ)
â¦200% of the initial speciï¬ed value
Leakage current
â¦The initial speciï¬ed value
(Caution)
Surge Voltage Test intends to evaluate capacitors in durability of an exceptional excessive voltage under speciï¬c conditions.It does
not imply long-term use at all.
âDIMENSIONS [mm]
â Terminal Code : A
â Size code : F80 to JA0
Vent for JA0
W
â Terminal Code : G(Vibration resistant structure)
â Size code : HA0 and JA0
Vent for JA0
0.3max.
W
Size code D L A B C
W
P
F80 6.3 7.7 6.6 6.6 7.2 0.5 to 0.8 1.9
HA0
8 10.0 8.3 8.3 9.0 0.7 to 1.1 3.1
JA0
10 10.0 10.3 10.3 11.0 0.7 to 1.1 4.5
0.3max.
A±0.2
L±0.3 (Note)
Note : L±0.5 for HA0 and JA0
L±0.5
âMARKING
EX) 35V330µF
â Rated voltage symbol
3Q
330
VZR
Rated voltage (Vdc) 6.3
10
16
Symbol
j
A
C
A±0.2
: Dummy terminals
25
35
50
E
V
H
Applying voltage over the rated voltages causes the capacitors to have short lifetime.
Besides, applying voltage over the speciï¬ed surge voltages may cause to have short circuit failure. A protection
circuit should be used if applied voltage will exceed the rated voltages.
Product specifications in this catalog are subject to change without notice.Request our product specifications before purchase and/or use. Please use our products based on the information contained in this catalog and product specifications.
96
CAT. No. E1001Q
|
▷ |