English
Language : 

AV10 Datasheet, PDF (1/1 Pages) celduc-relais – HIGH VOLTAGE REED SWITCH NORMALY OPEN, DRY CONTACT
INTERRUPTEUR REED HAUTE TENSION
HIGH VOLTAGE REED SWITCH
NORMALEMENT OUVERT, CONTACT SEC
NORMALY OPEN, DRY CONTACT
I/SEC/AV10/B/14/09/2005
page 1 / 1 F/GB
AV10 . . . .
10,5 mm max
13 mm max
Ø 5,5 mm max
50,8 mm max
83,5 mm max
Ø1,4
CARACTERISTIQUES ELECTRIQUES / ELECTRICAL DATA
Puissance maxi commutable / Max. switching power
Tension maxi commutable / Max. switching voltage
Courant maxi commutable / Max. switching current
Courant passant maximum / Carrying current
Tension typique de tenue / Typical dielectric strength
50 VA
7 500 VDC
0,3A
3A
10 000 VDC
Résistance de contact initiale ( max ) / Initial contact resistance
Méthode de mesure / Test process
Résistance d'isolement ( min ) / Insulation resistance
Temps de commutation maximum à l'action ( rebonds inclus ) /
Switching time / max. operate time ( bounces included )
≤ 100 mΩ
1010 Ω
3 ms
Référence ( Plage standard d'Ampères Tours de fermeture ) /
Reference ( standard pull-in value )
AV10100120 ( de 100 à 120 ATf ) /
from 100 up to 120 AT
Pour des applications particulières ( autres sensibilités, plage réduite, coupe, cambrage ), prière de nous consulter.
For special applications ( others pull-in-range, reduced range, cutting out, bending ), please contact us
EXEMPLE/ EXAMPLE : AV1080100 ( de 80 à 100 ATf ) / from 100 up to 120 AT )
Proud to serve you
All technical caracteristics are subject to change without previous notice.
Caractéristiques sujettes à modifications sans préavis.
celduc
relais