English
Language : 

AC011015 Datasheet, PDF (1/2 Pages) celduc-relais – REED SWITCH NORMALY OPEN, DRY CONTACT
INTERRUPTEUR REED
REED SWITCH
NORMALEMENT OUVERT, CONTACT SEC
NORMALY OPEN, DRY CONTACT
I/SEC/AC011015/A/26/09/2000
page 1 / 2 F/GB
AC011015
Ø 1,4 max
5,4 max
26,7
Ø 0,25
CARACTERISTIQUES ELECTRIQUES / ELECTRICAL DATA
Puissance maxi commutable / Max. switching power
Tension maxi commutable / Max. switching voltage
Courant maxi commutable / Max. switching current
Tension typique de tenue / Typical dielectric strength
Résistance de contact initiale ( max ) / Initial contact resistance
Résistance d'isolement ( min ) / Insulation resistance
Capacité / Capacitance
0,25 W
30 VDC
10 mA
150 Vdc
≤ 500 m
109
0,2 pF
Temps de commutation
Méthode de mesure / Test process ---> Alimentation de bobine /Coil voltage : ATF + 50%
à l'action ( rebonds inclus ) / Operate time ( bounces included )
0,2 ms
au relâchement / Release time
0,05 ms
Proud to serve you
All technical caracteristics are subject to change without previous notice.
Caractéristiques sujettes à modifications sans préavis.
celduc
relais