English
Language : 

ZICM357SP2-1C Datasheet, PDF (6/18 Pages) California Eastern Labs – Integrated Transceiver Modules for ZigBee / IEEE 802.15.4 Development Kit available: ZICM-EM35X-DEV-KIT-2
EM357 Mini Modules
ABSOLUTE MAXIMUM RATINGS
Description
Power Supply Voltage (VDD)
Voltage on any I/O Line
RF Input Power
ZICM357SP0
ZICM357SP2
Storage Temperature Range
Reflow Soldering Temperature
MeshConnect ZICM357SPx Module
Min
Max
-0.3
3.6
-0.3
VDD + 0.3
–
+15
–
+5
-40
125
–
260
Unit
VDC
VDC
dBm
°C
°C
Note: Exceeding the maximum ratings may cause permanent damage to the module or devices.
RECOMMENDED (OPERATING CONDITIONS)
Description
Power Supply Voltage (VDD)
Input Frequency
Ambient Temperature Range
MeshConnect ZICM357SPx Module
Min
Typ
Max
2.1
3.3
3.6
2405
–
2480
-40
25
85
Unit
VDC
MHz
°C
DC CHARACTERISTICS (@ 25⁰ C, VDD = 3.3V, ZICM357SP0 TX Power Mode 1, ZICM357SP2 TX Power Mode 2)
Description
MeshConnect ZICM357SPx Module
Unit
Min
Typ
Max
Transmit Mode Current @ 8 dBm
–
44
–
mA
Transmit Mode Current @ 0 dBm
ZICM357SP0
–
31
–
mA
Receive Mode Current
–
30
–
mA
Transmit Mode Current @ 20 dBm
–
150
–
mA
Transmit Mode Current @ 0 dBm
ZICM357SP2
–
58
–
mA
Receive Mode Current
–
34
–
mA
Sleep Mode Current
–
1
–
µA
RF CHARACTERISTICS (@ 25⁰ C, VDD = 3.3V, ZICM357SP0 TX Power Mode 1, ZICM357SP2 TX Power Mode 2)
Description
MeshConnect ZICM357SPx Module
Unit
Min
Typ
Max
General Characteristics
RF Frequency Range
2405
–
2480
MHz
RF Channels
11
–
26
–
Frequency Error Tolerance
-96.2
–
96.2
kHz
Transmitter
Maximum Output Power
–
8
–
dBm
Minimum Output Power
ZICM357SP0
–
-40
–
dBm
Offset Error Vector Magnitude
–
5
35
%
Maximum Output Power
(using Power Mode 2, Power Setting -2)
–
Minimum Output Power
ZICM357SP2
–
20
21
dBm
-40
–
dBm
Offset Error Vector Magnitude
–
5
35
%
Receiver
Sensitivity (1% PER, boost mode)
–
ZICM357SP0
Saturation (maximum input level)
0
-100
–
-94
dBm
–
dBm
Sensitivity (1% PER, normal mode)
–
Saturation (maximum input level)
ZICM357SP2
-10
-103
–
-97
dBm
–
dBm
Note: For the ZICM357SP2 Module, Power Mode 2 with Power Setting -2 is the maximum setting allowed for FCC
Compliance. Operating in Power Mode 3 at higher power settings may damage the PA.
This document is subject to change without notice
Document No: 0011-00-07-00-000 (Issue H)
Page 6